Composite Encyclopedia | Nabak Composite

Joining Methods for Composite Parts: An Engineering Guide to Bolted, Riveted, Bonded and Hybrid Joints in FRP Structures

Most failures in composite structures do not start in the middle of a beam or column but at the joint. A pultruded profile has strength comparable to steel in the longitudinal direction, but the bolt hole, the cut edge and nut pressure are its weak points. A correct joint means knowing where to drill, with which drill, how far from the edge, with which washer and to what torque, and when adhesive or a combination of adhesive and bolts is better. In this article we look at the methods of joining composite parts with figures, tables and practical details — from mechanical joints and adhesive bonds to hybrid joints.

Publisher: Nabak Composite Topic: Joining composite parts Reading time: about 17 minutes

Why is joining composite parts an engineering subject?

Most structures cannot be made in one piece, or it is not economical to do so; platforms, handrails, stairs, cable tray supports and covers are built from separate profiles and parts joined on site. Unlike steel, thermoset composite parts cannot be welded, because cured resin does not melt. For this reason, the methods of joining composite parts fall into three main groups:

  1. Mechanical joints: bolts and nuts, rivets, pins and self-tapping screws.
  2. Adhesive joints: joining two surfaces with a structural adhesive.
  3. Hybrid joints: using adhesive and mechanical fastening together.
Bolted mechanical connection of composite profiles with a stainless steel bracket
Bolted connection of composite box profiles with a bracket and stainless steel bolts and nuts. (illustrative image)

Joints are critical in composites because their properties are anisotropic: a pultruded profile is very strong in the fiber (longitudinal) direction, but its transverse strength, interlaminar shear strength and bearing resistance are lower, and its behavior up to failure is almost linear with no yielding. So, unlike steel, stress at a joint is not redistributed between bolts by local yielding, and the joint geometry matters more. See the design principles in design and analysis of composites.

≥ 4dHole center-to-center spacing
≥ 2.5dHole-to-edge distance
≥ 3dFlat washer outer diameter
316Recommended stainless steel
0Welding and hot work

Mechanical versus adhesive joints in composites

The choice between a mechanical and an adhesive joint depends on part thickness, load type, environmental conditions, the need for disassembly and the workshop facilities. The table below compares the advantages and disadvantages of each method:

CriterionMechanical joints (bolt, rivet, pin)Adhesive joints
Thickness limitNone; suits thick partsMore efficient for thin to medium parts
Disassembly and inspectionCan be taken apart and inspected without damagePermanent; inspection needs non-destructive methods
PreparationAccurate drillingSurface preparation, environmental control and cure time
Stress concentrationSevere concentration at the hole edgeSpread over the area; stress peaks at both ends of the overlap
Fiber cuttingThe hole cuts the fibersFibers stay intact
WeightBolts and connection plates add weightLighter
Fatigue and sealingSensitive to slack and moisture ingress through the holeGood fatigue performance and sealed
Sensitivity to environment and workmanshipLow; simple to do on siteHigh; sensitive to temperature, humidity and surface cleanliness
Residual stress and corrosionCreates no residual stressMay arise from cure shrinkage and differential thermal expansion
Failure behaviorGradual (especially in bearing)Often sudden
Data correction: some sources state that "mechanical joints generally carry more load than adhesive joints" and that "there is no stress concentration in an adhesive joint". Both statements need correcting: in thin parts (usually below about 5 to 6 mm) a well-designed adhesive joint is more efficient than a bolted joint, whereas in thick parts the mechanical joint is superior. And in an adhesive joint, the shear stress and peel stress at both ends of the overlap are several times the average stress; the stress concentration is lower than at a bolt hole, but not zero. As for corrosion, glass composite does not corrode; the risks at a hole are moisture ingress into the cut fibers and corrosion of the metal bolt itself.

Mechanical joints in composite parts

Mechanical joints are the most common way of joining composite parts in pultruded structures, platforms and handrails. The types of mechanical joint are:

Bolt, nut and washerThe main structural mechanical joint; can be taken apart.
RivetFor thin parts and sheets; fast installation from one side.
PinSteel or composite pin used with adhesive.
Self-tapping screwFor lightly loaded parts and covers; a self-tapping screw needs a pilot hole.

Drilling composite parts

Every mechanical joint starts with drilling, and the quality of the hole determines the quality of the joint. The greatest risk when drilling composites is delamination and fraying of the fibers on the entry side and especially the exit side of the drill. To prevent it:

  • Use a sharp diamond or carbide drill; an ordinary HSS drill blunts quickly and tears the fibers.
  • Keep the feed force on the drill low and steady, especially as the drill breaks through; place a backing board (wood or scrap composite) under the part.
  • Choose a suitable cutting speed and a slow feed, and where possible use coolant (water) to reduce heat and dust.
  • Choose a drill about 0.5 to 1 mm larger than the bolt diameter (a close-clearance hole). In structural joints where load sharing between bolts matters, less clearance is better.
  • Seal the hole wall and cut edges with resin so that moisture cannot penetrate the cut fibers.

See tooling and speeds in cutting and machining composites.

Hole location: hole spacing and edge distance

The spacing between holes and the distance from a hole to the outer edge of the composite part determine the failure mode of the joint. Too small a spacing makes the stress concentrations around the holes overlap and causes premature failure of the joint in brittle modes (shear-out or cleavage).

In the table below, d is the hole diameter. To reach maximum bearing capacity and gradual failure, a larger end distance e (about 4 × d) is recommended.

Meeting these distances in narrow parts such as flat bars and channel flanges limits the number and diameter of bolts that can be used; in that case the usual solution is to use two smaller bolts instead of one large bolt, or to widen the connection plate.

Hole spacing and hole-to-edge distance in a mechanical joint of composite parts
Hole spacing symbols: e, c, p₁, p₂ and hole diameter d.
ParameterSymbolMinimum allowable distance
Hole center to end edge (in the load direction)e2.5 × d
Hole center to side edgec2.5 × d
Hole center-to-center spacing in the load directionp₁4 × d
Hole center-to-center spacing perpendicular to the loadp₂4 × d

Failure modes of bolted composite joints

A bolted composite joint can fail in one of the modes below. The aim of design is to make bearing the failure mode through correct spacing, because it is the only mode that develops gradually and gives warning (deformation and slack) before complete failure:

Bearing Net-section tension Shear-out Cleavage Load P downward; bolt near the top of the composite strip (top edge = end edge e)
The four main failure modes of a bolted FRP profile joint; in addition, bolt head pull-through and failure of the bolt itself are also possible.
  • Bearing: crushing of the composite in front of the bolt; the desirable mode. Its main drawback is increasing slack.
  • Net-section tension: failure of the remaining section beside the hole; when the side distance c or the part width is small.
  • Shear-out: a piece of the part in front of the bolt is pushed out along the fibers; when the end distance e is small. Very common in pultrusion because of the low shear strength.
  • Cleavage: a combination of tension and shear — a longitudinal crack from the hole to the edge. Occurs with a small end distance and few transverse fibers.
Engineering view — estimating the bearing capacity of one bolt: the bearing capacity is given by Pbr = d × t × σbr. For an M12 bolt in a 10 mm profile wall with a longitudinal bearing strength of 150 MPa (the EN 13706 grade E23 minimum): Pbr = 12 × 10 × 150 = 18,000 N ≈ 18 kN (characteristic value). With a safety factor of about 3, the allowable load per bolt is about 6 kN. By comparison, the shear capacity of the M12 A4-70 stainless bolt itself is about 35 kN — so in a bolted composite joint it is almost always the composite, not the bolt, that governs. In the transverse (90°) direction the bearing strength is about half, so transverse load on a hole must be checked more carefully. See the related test standards (ASTM D953, ASTM D5961 and EN 13706) in composite testing standards.

Technical tips for a good mechanical joint

  • Two wide flat washers: one under the bolt head and one under the nut, to spread the pressure evenly and prevent surface crushing. The outer diameter of the flat washer should be at least 3 times the hole diameter.
  • Locking the nut: to prevent loosening under vibration, use a spring (lock) washer on top of a metal flat washer, or preferably a nylon-insert lock nut. A spring washer must never bear directly on the composite surface, because its sharp edge digs into the resin.
  • Sleeves in hollow and thick sections: in box sections, tubes and thick parts, use a composite, plastic or metal sleeve (spacer) sized to the hole to increase resistance to tightening torque and prevent the walls from being crushed.
  • Limited torque: the torque needed to tighten a bolt in a composite part is lower than in metal. Tighten bolts "firmly", not "as tight as possible"; use a torque wrench and the values recommended by the manufacturer. Excessive torque causes crushing, resin cracking and delamination at the joint.
  • Bolt material: in corrosive environments, 316 (A4) stainless steel is the first choice; the cheaper 304 (A2) stainless steel can be used in milder environments or if 316 is not available. Galvanized steel in a corrosive environment will not last as long as the composite. For electrically insulating applications, use composite (FRP) bolts and nuts.
  • Self-tapping screws: only for lightly loaded parts (covers, lids, light frames). First drill a pilot hole of about the thread root diameter (usually about 2 mm smaller than the nominal screw diameter), then install the self-tapping screw. Self-tapping screws have limited pull-out capacity in composites.
  • Rivets: for thin parts such as sheets, ducts and covers; use stainless or aluminum rivets with backing washers, or large-flange rivets, so the composite does not crack.
  • Pins: a steel or composite pin is inserted into a pre-drilled hole with adhesive; common in handrail and stair connections.
Data correction: some sources recommend a spring washer "before the nut" without qualification. A spring washer must sit on a metal flat washer, not on the composite surface; and in composite structures, a nylon-insert lock nut or thread-locking adhesive is often the better choice, because a spring washer loses its effectiveness as the composite gradually compresses (creeps).

Practical details of mechanical joints in composite structures

In profile structures, column-to-base-plate, column-to-beam and beam-to-beam connections are made with composite or steel angles and connection plates and bolts. The examples below show common connection details for channel, box and I-section profiles (each figure shows the connection view and section A-A):

Composite channel to composite flat bar connection with bolts and nuts
Channel to flat bar connection — a flat bar hanger below a channel beam.
Composite channel column to floor base plate connection
Channel column to floor base plate with connection angles.
Composite box column to floor base plate connection with a through-bolt
Box column to floor base plate; in a box section, a sleeve or local filling prevents the walls from being crushed.
Composite I-section column to floor base plate connection
I-section column to floor base plate with angles on both sides of the web.
Composite box column to composite channel beam connection
Box column to channel beam connection.
Composite I-section column to channel beam connection
I-section column to channel beam connection.
Composite I-section column to I-beam connection with connection angles
I-section column to I-beam connection with web and flange angles.
Horizontal connection of two nested composite channel beams
Horizontal connection of two nested channel beams.
Horizontal connection of two composite I-beams
Horizontal connection of two I-beams (secondary beam to main beam).
Design tips for column and beam connection details: (1) use at least two bolts in each connected member so the joint is stable against rotation; (2) composite angles and connection plates (pultruded fiberglass angle) should be at least as thick as the wall of the main member; (3) bolted connections of FRP profiles are usually treated as "pinned", and full moment transfer should not be expected from them — lateral stability must come from bracing; (4) in a column-to-base-plate connection, the steel base plate is anchored to the foundation with anchor bolts and the composite column is bolted to the base plate with angles.

Joint selection table for composite profiles and parts

The table below summarizes the recommended method — mechanical, adhesive or hybrid — for the most common details in composite structures, from an I-section column to base plate through to sheet and pipe joints:

Connection detailRecommended methodPractical note
Channel to flat barMechanical joints (bolts and nuts)At least two bolts; wide washer on the flat bar
Channel column to floor base plateBolts and nuts with anglesFiberglass or steel angle on both sides of the channel web
Box column to floor base plateThrough-bolt with sleeveSleeve inside the box section to prevent wall crushing
I-section column to floor base plateBolts and nuts with anglesConnect the web of the I-section column; flanges free
Box column to channel beamMechanical or hybrid jointsThrough-bolt in the box section with sleeve; adhesive for extra stiffness
I-section column to channel beamBolts and nutsThe channel beam is bolted to the flange of the I-section column
I-section column to I-beamWeb and flange connection anglesPinned connection; lateral bracing required
Two nested channel beamsBolts and nutsSufficient overlap and hole spacing ≥ 4d
Horizontal connection of two I-beamsAngles and boltsCope the flange of the secondary beam and connect to the web of the main beam
Fiberglass sheet and coversRivets, self-tapping screws or adhesive jointsWide sealing washer; pre-drilling
Fiberglass pipeAdhesive joints (spigot and socket) or bolted flangesBonding with resin and surface preparation
Composite gratingM and C clipsNo drilling of the panel

In all these joints, following the drilling and spacing rules controls stress concentration. Unlike metals, corrosion of the composite itself is not an issue in composite parts; but corrosion of metal bolts and connection plates, and galvanic corrosion where carbon fiber touches aluminum or steel, must be controlled by choosing 316 stainless steel or insulating between the surfaces.

Adhesive joints in composite parts

In an adhesive joint, two surfaces are joined by a layer of structural adhesive. With a suitable bonding process, two composite parts, or a composite part and a metal part, can be bonded together. When bonding composite to metal, the difference in thermal expansion (especially with aluminum) means temperature changes create additional stress in the bond line, which must be controlled by choosing a more flexible adhesive and a suitable bond-line thickness. In addition, gaps and clearances in mechanical joints can be filled with a special adhesive so that load is shared better between the bolts.

Types of adhesive joint in composites

The three main types of adhesive joint (lap, stepped and scarf) are chosen according to part thickness and joint location. The quality of these adhesive joints depends more on bonding workmanship and surface preparation than on the type of adhesive.

  • Single-lap joint: the simplest and most common; because the load path is eccentric, it has high peel stress at the edges.
  • Double-lap joint and strap joint: eliminate secondary bending and roughly double the capacity.
  • Stepped joint: thickness reduced in steps; suits thick parts.
  • Scarf joint: the most efficient adhesive joint, with almost uniform stress distribution; widely used in repairing composite parts, but requires precise machining.
Types of composite adhesive joint: single-lap, double-lap, stepped and scarf
Types of adhesive joint: single-lap and double-lap, stepped, scarf and strap joints.
Average stress τ = P/(b·L) Peak shear and peel stress at the ends Overlap length L (single-lap joint)
Illustrative distribution of shear stress along the overlap of an adhesive joint: stress peaks at both ends, which is why increasing the overlap length beyond a certain point does not add capacity.

Steps in bonding composite parts

  1. Surface preparation: sanding (about P80 to P120) to remove the glossy resin layer and mold release, or removing the peel ply just before bonding.
  2. Cleaning: removing dust and wiping with a suitable solvent (acetone or isopropyl alcohol), then waiting for it to evaporate completely.
  3. Applying the adhesive: epoxy, methacrylate (MMA) or polyurethane structural adhesives at the exact mix ratio; bond-line thickness usually 0.2 to 1 mm (per the adhesive datasheet).
  4. Assembly and fixing: placing the parts within the adhesive's working time and holding them with clamps or temporary bolts without excessive pressure.
  5. Curing: observe the cure time and temperature before loading; low ambient temperature lengthens the cure time.
Steps in bonding composite parts: drilling, surface preparation, applying adhesive and assembly
Steps for an adhesive and hybrid joint on a composite profile: drilling, surface preparation, applying adhesive and assembly with bolts.

See the standard adhesive joint tests (ASTM D5868 and ASTM D3163) in the composite testing standards article. Choosing a compatible resin and adhesive is also explained in types of composite resin.

Hybrid mechanical and adhesive joints

One of the most reliable ways of joining composite parts is to use adhesive and bolts together. In these hybrid joints, the adhesive, being stiffer, carries most of the service load with an even distribution over the area, fills the hole clearances and seals the joint; the bolts act as clamps while the adhesive cures and, if the adhesive is damaged or ages, act as a "fail-safe" backup load path that prevents sudden failure of the joint. The result is a relatively monolithic joint, higher fatigue resistance and safer failure behavior.

Design note: in a hybrid joint, the capacities of the adhesive and the bolts cannot simply be added together; because the adhesive is much stiffer than a bolted joint with clearance, it takes almost all the load while it is intact. A conservative design takes the bolts alone as sufficient for the ultimate load and uses the adhesive for stiffness, sealing and fatigue.

Welding composites: only for thermoplastics

Thermoset composite parts cannot be welded; but thermoplastic-matrix composites (such as fiber-reinforced polypropylene and polyamide) can be joined by ultrasonic welding, induction welding, resistance welding or hot plate welding. These methods are growing in the automotive and aerospace industries but are not common in pultruded products and grating.

Joining and installing Nabak composite products

Nabak profiles — composite channels, composite I-beams, box sections and composite flat bars — are compatible with all the mechanical and adhesive joints in this article; corrugated fiberglass and flat sheets are installed with rivets or self-tapping screws, fiberglass pipe with adhesive and flanged joints, and composite rods and polymer bars with pins and adhesive. Mechanical and adhesive joints are used to install all kinds of composite products, including fiberglass sheet (corrugated fiberglass), composite grating, composite box sections, fiberglass angles, composite channels, composite beams, fiberglass pipe, composite flat bars, polymer rods, composite wire and cable trays and ladders. For grating, special clips (M and C type) fix the grating to the substructure beam without drilling the panel; see the details in the grating selection guide.

Structural profilesBox sections, angles, channels, I-beams and flat bars; bolted connections.
Composite gratingMolded and pultruded; fixed with clips.
Sheet and pipeFiberglass sheet; rivets, self-tapping screws or adhesive.
Electrical equipmentCable trays and ladders and polymer rods; composite bolts for full insulation.
Nabak composite products, including profiles, grating and fiberglass pipe, that can be joined with bolts and adhesive
Nabak Composite products.
Nabak pultruded composite flat bar, suited to connection plates and base plates
Wide pultruded flat bar — suited to connection and splice plates.
Nabak pultrusion line — transverse mat fibers for bearing resistance in bolted joints
Transverse mat layers in pultrusion increase the bearing and cleavage resistance of bolted joints.

Checklist for joining composite parts

This checklist turns the joining methods described into practical steps in the workshop and on site:

  1. Choose the method: thick part or need for disassembly → mechanical joint; thin part or sealing → adhesive joint; critical joint or vibration → hybrid joint.
  2. Check the geometry: hole-to-edge distance at least 2.5d and hole spacing at least 4d.
  3. Drill correctly: diamond drill, low pressure, backing board, drill 0.5 to 1 mm larger than the bolt.
  4. Seal: seal the hole wall and cut edges with resin.
  5. Complete the fixings: two wide flat washers, lock nut, sleeve in hollow sections.
  6. Limit the torque: torque wrench and the manufacturer's values; no surface crushing.
  7. Control adhesive joints: bond only to sanded, clean surfaces; record cure temperature and time.
  8. Inspect: after a few weeks in service, inspect the bolts and retighten if necessary.

Frequently asked questions about joining composite parts

Can composite parts be welded?

Thermoset composite parts such as polyester and vinyl ester profiles and grating cannot be welded, because cured resin does not melt. They are joined with bolts and nuts, rivets, pins, adhesive or a combination of adhesive and bolts. Only thermoplastic composites can be welded, with methods such as induction or ultrasonic welding.

What is the minimum distance from a bolt hole to the edge of a composite profile?

As a general rule, the distance from the hole center to the end edge and the side edge is taken as at least 2.5 times the hole diameter, and the hole center-to-center spacing as at least 4 times the hole diameter. For maximum bearing capacity, a larger end distance (about 4 times the diameter) is recommended.

Is an adhesive joint or a mechanical joint better?

Neither is absolutely better. An adhesive joint is more efficient and lighter for thin parts, sealed joints and spreading stress over a large area; a mechanical joint is better for thick parts, joints that must be taken apart, easy inspection and on-site installation. In pultruded structures, the bolted joint is the most common method and the hybrid joint the most reliable.

What bolts are suitable for joining composite profiles?

In corrosive environments, 316 stainless steel bolts, nuts and washers are the first choice, and 304 stainless steel can be used in milder environments. For electrically insulating applications, composite (FRP) or polymer bolts and nuts are used. Always use a wide flat washer under the bolt head and under the nut.

Why should bolts in composite parts not be over-tightened?

Composites have lower through-thickness compressive strength than metal. Excessive torque causes surface crushing, resin cracking and delamination around the hole, especially in hollow sections such as box sections and tubes. Bolts should be tightened to the manufacturer's recommended torque with a wide washer or sleeve.

Summary

Thermoset composite parts are joined by three main methods: mechanical joints (bolts and nuts, rivets, pins and self-tapping screws), adhesive joints (lap, stepped and scarf) and hybrid joints. In a mechanical joint, drilling quality, hole-to-edge distance (at least 2.5 times the diameter), hole spacing (at least 4 times the diameter), two wide flat washers, sleeves in hollow sections, 316 stainless steel bolts and limited torque are decisive, and joint capacity is usually limited by bearing in the composite, not by the bolt itself. Adhesive joints are light and efficient for thin parts but need careful surface preparation and quality control; hybrid joints combine the benefits of both with safer failure behavior. Following these principles, Nabak profiles and composite products form integrated, durable structures with no need for welding.

Nabak Composite

This article was prepared by the technical team of Nabak Composite, a manufacturer of grating, pultruded profiles, sheets and composite products.