Product Datasheets | Nabak Composite

50×23 Pultruded Grating (I50-23): Long-Span Pultruded Grating with 57% Open Area — Specifications, Weight and Load Table

For spans longer than a meter, many designers turn to dense 38 mm grating; but 50×23 pultruded grating, with a 50×15×4.5 mm I-section at a 38 mm pitch, is lighter, has more capacity and provides 57% open area for drainage and airflow. In this datasheet we cover its dimensions, its 19 kg weight, section properties (correcting a common error in the section modulus), load table, comparison with the sister models, installation, assembly and surfaces of this pultruded composite grating.

Publisher: Nabak Composite Product: Pultruded grating I50-23 Reading time: about 12 minutes

What is 50×23 pultruded composite grating?

Pultruded composite grating is a type of composite mesh panel in which composite I-sections are laid parallel to each other and tied and assembled at set intervals by transverse rods or profiles. The load-bearing bars are made by pultrusion: resin-wetted glass roving and mat are pulled continuously through a hot die, and the longitudinal fibers remain continuous along the whole length of the bar. The result is a bar with several times the bending stiffness and strength of molded grating in the longitudinal direction. The product is also known as pultruded FRP grating, pultruded GRP grating, pultruded GFRP grating and pultruded fiberglass grating; pultruded GRP and GFRP grating are the same glass fiber (fiberglass) pultruded composite grating.

The code "50×23" or "I50-23" states two main properties: a 50 mm height for the load-bearing bar and a 23 mm opening between the flanges of two adjacent bars. This model combines the deepest section in the pultruded family with an open layout; the result is a grating that covers spans of 1000 to 1200 mm with low weight and excellent drainage. For an overall comparison of grating types, see the FRP grating selection guide.

50×23 pultruded composite grating with 50 mm deep yellow I-sections and a 23 mm opening
Grooved 50 mm I-sections of pultruded grating; bar pitch 38 mm.

Specifications and dimensions of 50×23 pultruded grating

Main specifications and dimensions of 50×23 pultruded composite grating in brief:

50 mmGrating height
23 mmOpening
38 mmCenter-to-center
57 %Open area
19 kg/m²Approx. weight

The load-bearing bar is a fiberglass I-section measuring 50×15×4.5 mm (depth × flange width × thickness), assembled with transverse composite profiles. This is the same section used in the 50×10 model; the only difference is the density of the layout.

The composite I-sections are at 38 mm centers, giving about 26.3 load-bearing bars per meter of width. Subtracting the 15 mm flange width from the 38 mm pitch gives a 23 mm opening, and allowing for the cross rods the open area of the pultruded grating comes to about 57 percent.

50×23 pultruded grating I-section dimensions: 50 mm depth, 15 mm flange width, 4.5 mm thickness, 23 mm opening
50×15×4.5 I-section and geometric specifications of 50×23 pultruded grating.
PropertyValueEngineering note
Load-bearing bar sectionI-section 50×15×4.5 mmPultruded fiberglass profile with longitudinal fibers
Grating height50 mmThe deepest pultruded grating section
Grating opening23 mmFast drainage of water, snow and mud
I-bar center-to-center38 mmAbout 26 bars per meter
Open area of the pultruded grating57%Lets air and light through; reduces wind load
Approximate weight per m²19 kgAbout 30% lighter than the 50×10 model
Standard resinIsophthalic polyesterVinyl ester and fire-resistant grade made to order

Weight of 50×23 pultruded composite grating

The approximate weight of 50×23 pultruded grating is 19 kg per m². A 1×3 m panel weighs about 57 kg and two people can carry it without lifting equipment. This weight is lower than the 50×10 model roughly in proportion to the number of bars (26.3 versus 40).

An important point for the designer: this model is about 5 kg per m² lighter than 38×10 grating at 24 kg/m², yet it has more load capacity. On a 200 m² platform this difference means about one tonne less dead load on the structure.

Approximate weight of one square meter of 50×23 pultruded grating, 19 kg, on a scale
Approximate weight of 1 m² of 50×23 pultruded grating: about 19 kg.

Section properties of 50×23 pultruded grating

The geometric properties of the composite section per meter of grating width — cross-sectional area, section modulus and moment of inertia — are given in the table below:

Section property (per meter of width)ValueCheck from section geometry
Composite cross-sectional area9.37×10³ mm²≈ 26.3 bars × 355 mm² ✓
Section modulus S12.6×10⁴ mm³ *I ÷ 25 = 12.6×10⁴
Moment of inertia I3.14×10⁶ mm⁴≈ 26.3 × 119×10³ mm⁴ ✓
* Data correction: some sources give the section modulus of this model as "10.8×10⁴ mm³". For a symmetric section, S = I / (h/2) = 3.14×10⁶ / 25 ≈ 12.6×10⁴ mm³. Likewise, reducing the section modulus of the 50×10 model (18.9×10⁴) in proportion to the number of bars (26.3 to 40) also gives about 12.4×10⁴. The correct value is therefore about 12.6×10⁴ mm³.
σ = M / S   |   δ = 5·q·L⁴ / (384·E·I)   |   S = I / (h/2)
Consistency check against the load table: converting the ultimate uniform load at each span into a bending moment (M = qL²/8) and then into stress (σ = M/S) using the corrected section modulus gives about 126 MPa at a 400 mm span, about 125 MPa at 1000 mm and about 119 MPa at 1400 mm — almost the same failure stress as the 50×10 model (113 to 126 MPa), which is made from the same I-section. With 10.8×10⁴, the stress would reach about 145 MPa, inconsistent with the model of the same section — further confirmation of the correction above.

Features of pultruded composite grating

50×23 pultruded composite grating offers the inherent advantages of FRP composite with an unusual combination of great depth and low weight:

High strength, low weightImpact resistant; only 19 kg/m² at a 50 mm height.
Corrosion and UV resistantNo rust; UV resistant with a UV additive.
Electrically insulatingNon-conductive and non-magnetic.
Anti-slipGrooved or gritted surface to prevent slipping.
Low maintenanceNo periodic painting; the lowest upkeep cost.
Self-extinguishingSelf-extinguishing behavior in fire; higher grades made to order.
Long spansAllowable load of 1000 kg/m² at a 1200 mm span.
Drainage and ventilation57% open area for water, air and light; reduced wind load.

How pultruded grating sits on its supports

In pultruded grating the main load is transferred to the FRP I-bars, and the cross rods only restrain the bars and spread the load. The panel must therefore sit on the support seat with the panel length (the direction of the load-bearing bars) perpendicular to the support beams. Installing the panel crosswise reduces capacity to a small fraction of the table values.

Note: the minimum bearing length of pultruded grating on the supporting member is 25 mm. With the open 50×23 layout, make sure the panel edge on the support ends with a complete load-bearing bar and no bar is left unsupported.
Pultruded grating installation drawing: load-bearing bars perpendicular to the support and a 25 mm seat
Load-bearing bars perpendicular to the support, with a minimum 25 mm seat.
50×23 pultruded grating on a steel support beam with a minimum bearing length of 25 mm
50 mm I-sections bearing on the flange of the support beam — minimum bearing length 25 mm.

Installing fiberglass grating is straightforward. Panels are fixed to the substructure with stainless steel grating clips (M-clips, saddle clips or hold-down clips); fixing details and clip types are covered in the grating installation article. Because of its low weight and large open area, on windy open platforms this model must be restrained with at least four clips per panel. After cutting on site, seal the edges with resin (see cutting and machining composites).

Load capacity of pultruded composite grating

The loading of 50×23 pultruded composite grating is assessed in two cases: concentrated load, where the force is applied at a point or small area (an equipment leg, a wheel), and uniform load, where the force is spread over the whole surface (pedestrian traffic, storage). Two criteria are reported for each:

  • Allowable load based on deflection: the load that brings the mid-panel deflection to L/200 of the support spacing (0.5% of the span).
  • Ultimate (failure) load: the maximum load at which the grating panel will certainly fail.
Concentrated and uniform loads on pultruded composite grating
Concentrated (point) load and uniform (distributed) load.
Uniform load on a grating panel between two supports
Grating panel under uniform load between two supports.
Safety rule: for safety, the maximum service load must not exceed 40 percent of the ultimate load (a safety factor of 2.5). On pedestrian routes deflection is usually also limited to 6 mm.

Load table for 50×23 pultruded grating

The table below gives the allowable load at L/200 deflection and the ultimate load of 50×23 pultruded composite grating, for concentrated and uniform loading, at six common support spacings:

Support spacing (mm)Concentrated load (kg)Uniform load (kg/m²)
Allowable load at L/200 deflectionUltimate loadAllowable load at L/200 deflectionUltimate load
4001,75010,70030,00081,000
6007807,8008,90039,000
8004506,0503,70018,500
1,0002804,9001,85012,800
1,2001903,9501,0008,300
1,4001452,7006506,200
500 1,000 2,000 5,000 10,000 20,000 50,000 100,000 400 600 800 1,000 1,200 1,400 Ultimate load 40% of ultimate load (safety cap) Allowable load at L/200 deflection Support spacing (mm) Uniform load — kg/m² (log scale)
Allowable uniform load at L/200 deflection, ultimate load and the 40%-of-ultimate safety cap for 50×23 pultruded grating (logarithmic vertical axis).
Engineering reading of the table:
  • The allowable uniform load falls roughly with the cube of the span and the allowable concentrated load with the square; from 600 to 1200 mm the allowable uniform load drops about 9 times (8900 to 1000) and the allowable concentrated load about 4 times (780 to 190).
  • At spans of 600 mm and above, the deflection-based allowable load is clearly below 40% of the ultimate load (at a 1000 mm span: 1850 versus 5120), so deflection governs the design.
  • At a 400 mm span, the deflection-based allowable load (30,000) is close to 40% of the ultimate load (32,400); at this span both criteria must be checked.
  • A 1200 mm span is the ideal design point for this model: an allowable load of 1000 kg/m² at L/200 = 6 mm deflection, meeting both the structural criterion and the pedestrian comfort limit. At 1400 mm, take the allowable load as about 550 kg/m² for a 6 mm limit.

Load comparison with other composite gratings

Comparing the allowable uniform load at L/200 deflection (kg/m²) shows where this model sits in the composite grating family:

Grating typeWeight (kg/m²)800 span1000 span1200 span1400 span
Molded grating 50×50×50—1250650400—
Pultruded 38×2316.51900990570360
Pultruded 38×102428001450870550
Pultruded 50×2319370018501000650
Pultruded 50×1027.55540265014501000

At a 1 m span, 50×23 pultruded grating has about 2.8 times the capacity of 50 mm molded grating and 1.9 times that of 38×23 pultruded grating, while being only 2.5 kg per m² heavier than the 38×23 model. See the full tables in FRP grating load capacity tables, and the sister models in 50×10 pultruded grating, 38×10 pultruded grating and 38×23 pultruded grating.

Load design examples for pultruded composite grating

The examples below show step by step how to check loading against this model's table.

Example 1 — cooling tower walkway:1200 mm span, design uniform load 500 kg/m².
  • Allowable load at L/200 = 1000 ≥ 500 ✓; approximate deflection = 6 × 500/1000 = 3 mm.
  • Safety: 0.4 × 8300 = 3320 ≫ 500 ✓; the 57% open area lets air and water droplets pass freely.
Example 2 — equipment area:1000 mm span, uniform load 1500 kg/m².
  • Allowable load at L/200 = 1850 ≥ 1500 ✓; approximate deflection = 5 × 1500/1850 ≈ 4.1 mm.
  • Safety: 0.4 × 12800 = 5120 ≫ 1500 ✓; the 38×10 model, at 1450, was not sufficient in this case.
Example 3 — concentrated maintenance load:1000 mm span, concentrated load 200 kg.
  • Allowable concentrated load = 280 ≥ 200 ✓; approximate deflection = 5 × 200/280 ≈ 3.6 mm; safety: 0.4 × 4900 = 1960 ✓
Example 4 — checking a 1400 mm span:Load 800 kg/m²; allowable 650 < 800 ✗ → the 50×10 model (1000 at 1400) or reduce the span to 1200 mm.

50×23 pultruded grating compared with 38×10 and 50×10

Buyers of pultruded grating for long spans usually hesitate between these three models. The table below sets out their key specifications side by side:

Property50×2338×1050×10
Center-to-center spacing38 mm25 mm25 mm
Open area57%38%38%
Weight (kg/m²)192427.5
Moment of inertia (mm⁴)3.14×10⁶1.9×10⁶4.71×10⁶
Allowable uniform load at 1000 span185014502650
Allowable concentrated load at 1000 span280240400
Capacity per weight at 1000 span976096
Maximum span for a 1000 kg/m² load1200 mmapprox. 1100 mm1400 mm
Engineering conclusion:
  • 50×23 versus 38×10: the 50×23 model is about 20% lighter, with 28% more allowable uniform load and 50% more open area. If a 23 mm opening and 12 mm more height cause no problem for the project, 50×23 is the better choice in every respect.
  • 50×23 versus 50×10: structural efficiency (capacity per weight) is the same; choose 50×10 only when the span exceeds 1200 mm, there are heavy concentrated loads, or a fine opening is needed for heels and small wheels.

The 23 mm opening lets small tool parts through; in sensitive areas a composite cover plate or toe plate can be fitted over part of the grating, keeping the open-area advantage over the rest of the surface.

Assembly sections for pultruded composite grating

The I-sections of pultruded composite grating are assembled with two types of cross member:

1) Assembly with a composite locking profile: a slotted pultruded profile is locked over the flanges of the I-sections and fixed with screws or pins; the top surface is even, and individual bars can be replaced locally.

2) Assembly with composite rods: FRP composite rods are passed through holes in the webs of the I-sections and fixed with epoxy adhesive — a one-piece joint that spreads concentrated loads over several neighboring bars.

In the 50×23 model each load-bearing bar takes a larger share of a point load, so for concentrated loads cross members at 100 to 150 mm spacing are recommended.

Assembly of 50×23 pultruded grating with composite rods through the I-sections
Grid of I-sections and transverse composite rods.

Surface types of pultruded composite grating

Pultruded composite grating is produced with three surface types, chosen according to slip risk, the presence of oil and water, the slope of the route and the type of traffic. On slopes and in areas exposed to oil spills, high slip resistance is essential:

Pultruded grating surfaces: grooved, smooth and quartz-gritted
From right: grooved (anti-slip), smooth and gritted surfaces.
  • Grooved surface: longitudinal grooves formed on the top flange during production of the I-section prevent slipping; the standard option for platforms and walkways.
  • Smooth surface: a smooth, polished surface for special uses such as sports halls and hygienic areas. By turning the grating over, both surfaces can be used together — for example the smooth face in an indoor hall and the grooved face outdoors.
  • Gritted surface: a coating of quartz grit and sand of a defined grading bonded into a resin layer, increasing surface roughness on slopes, oily areas and wet routes and minimizing slip risk. For more roughness, the surface can also be sandblasted after production; sandblasting also gives a uniform roughness on a smooth surface.
Quartz grit and sand coated surface on pultruded composite grating
Gritted surface with quartz grit and sand to prevent slipping.

Applications of 50×23 pultruded grating

The composite surface is chosen to suit the environment of each application. The combination of long spans, low weight and large open area makes these composite mesh panels suitable where molded fiberglass grating lacks capacity and metal grating corrodes:

  • Cooling tower walkways and platforms with spans of 1000 to 1200 mm.
  • Covers for channels, basins and weirs in water and wastewater treatment plants.
  • Open platforms in petrochemical plants, refineries and power plants exposed to rain, snow and salt mist.
  • Access platforms in electrical substations, because it is insulating.
  • Industrial footbridges, jetties and coastal structures.
  • Refurbishing corroded steel platforms with wide beam spacing, without adding dead load.
Shipping yellow composite grating panels by trailer from Nabak Composite to a project
Shipping Nabak yellow pultruded composite (GRP) grating panels by trailer to a project site.

Pultruded composite grating compared with metal grating

Compared with metal grating, pultruded grating differs fundamentally in weight and durability. In wet and corrosive environments, 50×23 pultruded composite grating, with its long life and negligible maintenance, is an economical alternative to galvanized steel grating:

Feature50×23 pultruded composite grating (FRP composite)Galvanized steel grating
Weightapprox. 19 kg/m²Far heavier for similar capacity
CorrosionNone; resistant to UV and salt mistRusts once the zinc layer is damaged
Electrical conductivityFully insulatingConductive
Impact behaviorAbsorbs impact without permanent deformationPermanent denting
InstallationCut with simple tools; clips and bolted fixingsWelding and re-galvanizing of edges
Maintenance costVery lowPeriodic painting and repair

Ordering guide for pultruded grating

For an accurate price for 50×23 pultruded composite grating, prepare the following information; the loading conditions and span are the most important inputs for choosing the model:

  1. Panel size: length in the direction of the load-bearing bars, and panel width
  2. Span and loading: support spacing and uniform or concentrated load
  3. Assembly type: locking profile or composite rod
  4. Surface type: grooved, smooth or gritted
  5. Resin and color: polyester, vinyl ester or fire-resistant grade
  6. Clips: type and number of grating clips and the substructure

Pultruded grating production and delivery at Nabak Composite

Nabak Composite produces, cuts and assembles 25, 38 and 50 mm composite I-sections and cross rods for pultruded grating on its own pultrusion lines, and packs and ships panels in custom sizes and various colors with grooved, smooth or gritted surfaces. The light weight of the 50×23 model means that in transport the limit is usually load volume, not weight.

Glass roving bobbin creel on a Nabak pultrusion line
Roving bobbins — the source of the continuous longitudinal fibers in the I-sections.
Moving a bundle of grey composite grating by forklift in the Nabak yard
Moving a bundle of composite grating by forklift at Nabak.
Pallets of composite grating on a truck, ready to ship from the Nabak factory
Pallets of composite grating ready to ship from the Nabak factory.
Shipping yellow composite pultruded box profiles on a Nabak trailer
Shipping pultruded box profiles — composite substructure for grating platforms.
Nabak Composite showroom with grating and composite profiles
Nabak Composite product showroom.
25 mm pultruded grating15 mm and 25 mm openings for short spans.
38 mm pultruded grating10 mm and 23 mm openings for medium spans.
50 mm pultruded grating10 mm and 23 mm openings for long spans.
Clips and accessoriesStainless clips and composite substructure profiles.

Frequently asked questions about 50×23 pultruded grating

How much does 50×23 pultruded grating weigh?

The approximate weight of pultruded composite grating with a 50 mm height and a 23 mm opening is about 19 kg per m²; a 1×3 m panel weighs about 57 kg.

Is 50×23 or 38×10 pultruded grating better?

The 50×23 model is about 20% lighter than 38×10 and at a 1 m span has about 28% more allowable load (1850 versus 1450 kg/m²) and more open area (57% versus 38%); the only advantages of 38×10 are its finer opening and lower height.

What is the allowable load of 50×23 pultruded grating at a 1200 mm span?

The allowable uniform load at L/200 deflection for a 1200 mm span is 1000 kg/m² and the allowable concentrated load is 190 kg.

What is the correct section modulus of 50×23 pultruded grating?

For a symmetric section 50 mm deep, the section modulus equals the moment of inertia divided by 25: 3.14×10⁶ ÷ 25 ≈ 12.6×10⁴ mm³ per meter of width.

What is the minimum seat length for 50×23 pultruded grating?

The minimum bearing length of pultruded grating on the supporting member is 25 mm, and the load-bearing I-sections must be perpendicular to the support beams.

Summary

50×23 pultruded composite grating — with 50×15×4.5 mm I-sections at 38 mm centers, about 26 load-bearing bars per meter, 57% open area and a weight of 19 kg/m² — is the most efficient pultruded grating for spans of 1000 to 1200 mm. A moment of inertia of 3.14×10⁶ mm⁴ allows an allowable uniform load of 1850 kg/m² at a 1 m span and 1000 kg/m² at 1200 mm — lighter and stronger than the 38×10 model. Installed correctly (load-bearing bars perpendicular to the supports and a seat of at least 25 mm), with the right surface and the 40%-of-ultimate cap respected, this pultruded FRP grating is a light, insulating and durable alternative to steel grating.

Nabak Composite

This article was prepared by the technical team of Nabak Composite, a manufacturer of pultruded grating and composite products.