Product Datasheets | Nabak Composite

50×10 Pultruded Grating (I50-10): Extra Heavy-Duty Pultruded Grating for Long Spans — Specifications, Weight and Load Table

When substructure beams are more than a meter apart, or a platform has to carry heavy equipment, the 25 mm and 38 mm models reach their deflection limits. 50×10 pultruded grating, with a 50×15×4.5 mm I-section, 40 load-bearing bars per meter and a moment of inertia of 4.71×10⁶ mm⁴, is the highest-capacity pultruded composite grating in the Nabak range. In this datasheet we cover its dimensions, weight, section properties, load table, comparison with the 38×10 model, installation, assembly and surfaces, with sample calculations.

Publisher: Nabak Composite Product: Pultruded grating I50-10 Reading time: about 12 minutes

What is 50×10 pultruded composite grating?

Pultruded composite grating is a mesh panel from the composite grating family, made and assembled by placing composite I-sections side by side in parallel and tying them with transverse rods or profiles. The load-bearing bars are produced by pultrusion: resin-wetted glass roving and mat are pulled continuously through a heated die, and the longitudinal fibers run the full length of the bar. That is why the bending stiffness and strength of the grating along the load-bearing bars are several times those of molded grating. On the market the product is known as pultruded FRP grating, pultruded GRP grating, pultruded GFRP grating and pultruded fiberglass grating; pultruded GRP and GFRP grating are both the same glass fiber (fiberglass) pultruded composite grating.

In the code "50×10" or "I50-10", the first number is the 50 mm height of the load-bearing bar and the second is the 10 mm opening between the flanges of two adjacent bars. This model combines the deepest section with the densest layout, and it is designed for heavy equipment platforms, spans of 1200 to 1400 mm and routes that need both high capacity and the safety of a fine opening. For the other models, see the FRP grating selection guide.

50×10 pultruded composite grating with 50 mm deep yellow I-sections
Grooved 50 mm I-sections of pultruded grating with a cross rod.

Specifications and dimensions of 50×10 pultruded grating

Key specifications and dimensions of 50×10 pultruded composite grating at a glance:

50 mmGrating height
10 mmOpening
25 mmCenter-to-center
38 %Open area
27.5 kg/m²Approx. weight

The load-bearing bar of this model is a fiberglass I-section measuring 50×15×4.5 mm (depth × flange width × thickness), assembled with transverse composite profiles. The 4.5 mm thickness (against 4 mm in the 38 mm models) keeps the taller web and flange stable against local buckling under heavy loads.

The composite I-sections are at 25 mm centers, i.e. 40 load-bearing bars per meter of width. Of this pitch, 15 mm is the flange and 10 mm the opening, and allowing for the cross rods the open area of the pultruded grating is about 38 percent.

50×10 pultruded grating I-section dimensions: 50 mm depth, 15 mm flange width, 4.5 mm thickness
50×15×4.5 I-section and geometric specifications of 50×10 pultruded grating.
PropertyValueEngineering note
Load-bearing bar sectionI-section 50×15×4.5 mmPultruded fiberglass profile with longitudinal fibers
Grating height50 mmThe deepest pultruded grating section
Grating opening10 mmSafe for shoe heels and small wheels
I-bar center-to-center25 mm40 bars per meter
Open area of the pultruded grating38%Drainage and airflow
Approximate weight per m²27.5 kgOnly 15% more than the 38×10 model
Standard resinIsophthalic polyesterVinyl ester and fire-resistant grade made to order

Weight of 50×10 pultruded composite grating

The approximate weight of 50×10 pultruded grating is 27.5 kg per m². A 1×3 m panel weighs about 83 kg, so handling it needs three people or a light lifting aid. Importantly, increasing the height from 38 to 50 mm raises the weight by only about 15 percent, while load capacity rises by almost 80 percent. A steel grating of similar capacity at these spans is several times heavier and needs a stronger substructure.

Section properties of 50×10 pultruded grating

The geometric properties of the composite section per meter of grating width — cross-sectional area, section modulus and moment of inertia — are given in the table below and compared with the 38×10 model:

Section property (per meter of width)ValueRelative to the 38×10 model
Composite cross-sectional area14.1×10³ mm²1.4 times
Section modulus S18.9×10⁴ mm³1.9 times
Moment of inertia I4.71×10⁶ mm⁴2.5 times
σ = M / S   |   δ = 5·q·L⁴ / (384·E·I)   |   S = I / (h/2)

For a symmetric section, S = 4.71×10⁶ ÷ 25 = 1.88×10⁵ mm³, consistent with the datasheet figure (18.9×10⁴). Increasing the height from 38 to 50 mm (1.32 times), because the moment of inertia grows with the cube of the height and the web is thicker, raises bending stiffness about 2.5 times while material use rises only 1.4 times.

Consistency check of the failure data: converting the ultimate uniform load at each span into a bending moment (M = qL²/8) and then into stress (σ = M/S) gives about 126 MPa at a 400 mm span, about 123 MPa at 1000 mm and about 113 MPa at 1400 mm. The nearly constant failure stress across all spans shows that the load table is mechanically coherent and reliable.

Features of pultruded composite grating

50×10 pultruded composite grating, made from pultruded composite sections, combines the inherent advantages of FRP composite with the highest load capacity in the pultruded family:

High strength, low weightImpact resistant; far lighter than steel grating of equal capacity.
Corrosion and UV resistantNo rust; UV resistant with a UV additive.
Electrically insulatingNon-conductive and non-magnetic.
Anti-slip and safeGrooved or gritted surface against slipping; a safe 10 mm opening.
Low maintenanceNo periodic painting or repair; the lowest upkeep cost.
Self-extinguishingSelf-extinguishing behavior in fire; higher grades made to order.
Long spansCovers a 1400 mm span with an allowable load of 1000 kg/m².
Less substructureFewer, more widely spaced support beams; savings in structural steel.

How pultruded grating sits on its supports

In pultruded grating the main load is carried by the FRP I-bars, and the cross rods restrain the bars and spread the load. The panel must therefore sit on the support seat with the panel length (the direction of the load-bearing bars) perpendicular to the support beams. On the 50×10 model, which is chosen for long spans, any error in installation direction drastically reduces capacity.

Note: the minimum bearing length of pultruded grating on the supporting member is 25 mm. Because the support reactions are larger with this model, the flange of the substructure beam should be wide enough to give a seat of 40 mm or more.
Pultruded grating installation drawing: load-bearing bars perpendicular to the support and a 25 mm seat
Load-bearing bars perpendicular to the support, with a minimum 25 mm seat.
50×10 pultruded grating on a steel support beam with a minimum bearing length of 25 mm
50 mm I-sections bearing on the flange of the support beam — minimum bearing length 25 mm.

Installing fiberglass grating is straightforward. Panels are fixed to the substructure with stainless steel grating clips (M-clips, saddle clips or hold-down clips); fixing details and clip types are covered in the grating installation article. For the heavy panels of this model, use at least four clips per panel, and more on platforms with equipment vibration. After cutting, seal the edges with resin (see cutting and machining composites).

Load capacity of pultruded composite grating

Like the other models, the loading of 50×10 pultruded composite grating is assessed in two cases: concentrated load, where the force is applied at a point or small area (an equipment leg, a trolley wheel), and uniform load, where the force is spread over the whole surface (traffic, storage, distributed equipment dead load). Two criteria are given for each:

  • Allowable load based on deflection: the load that brings the mid-panel deflection to L/200 of the support spacing (0.5% of the span).
  • Ultimate (failure) load: the maximum load at which the grating panel will certainly fail.
Concentrated and uniform loads on pultruded composite grating
Concentrated (point) load and uniform (distributed) load.
Uniform load on a grating panel between two supports
Grating panel under uniform load between two supports.
Safety rule: for safety, the maximum service load must not exceed 40 percent of the ultimate load (a safety factor of 2.5). On pedestrian routes deflection is usually also limited to 6 mm.

Load table for 50×10 pultruded grating

The table below gives the allowable load at L/200 deflection and the ultimate load of 50×10 pultruded composite grating, for concentrated and uniform loading, at six common support spacings:

Support spacing (mm)Concentrated load (kg)Uniform load (kg/m²)
Allowable load at L/200 deflectionUltimate loadAllowable load at L/200 deflectionUltimate load
4002,62016,05045,400121,000
6001,18511,65012,90058,100
8006608,8505,54027,600
1,0004007,2102,65019,000
1,2002805,9001,45012,430
1,4002154,0001,0008,900
500 1,000 2,000 5,000 10,000 20,000 50,000 100,000 200,000 400 600 800 1,000 1,200 1,400 Ultimate load 40% of ultimate load (safety cap) Allowable load at L/200 deflection Support spacing (mm) Uniform load — kg/m² (log scale)
Allowable uniform load at L/200 deflection, ultimate load and the 40%-of-ultimate safety cap for 50×10 pultruded grating (logarithmic vertical axis).
Engineering reading of the table:
  • The allowable uniform load falls roughly with the cube of the span and the allowable concentrated load with the square; for example from 600 to 1200 mm the allowable uniform load drops about 9 times (12,900 to 1450) and the allowable concentrated load about 4 times (1185 to 280).
  • At spans of 600 mm and above, the deflection-based allowable load is clearly below 40% of the ultimate load (at a 1000 mm span: 2650 versus 7600), so deflection governs the design.
  • At the short 400 mm span, the deflection-based allowable load (45,400) is very close to 40% of the ultimate load (48,400); at this span, check both criteria together. Using this model at a 400 mm span is, however, rarely economical.
  • At a 1400 mm span, L/200 deflection equals 7 mm; for a 6 mm pedestrian limit, take the allowable load as about 850 kg/m², which is still enough for heavy industrial platforms.

Load comparison with other composite gratings

Comparing the allowable uniform load at L/200 deflection (kg/m²) shows where this model sits among common composite gratings:

Grating typeWeight (kg/m²)800 span1000 span1200 span1400 span
Molded grating 50×50×50—1250650400—
Pultruded 25×1514.51600850550350
Pultruded 38×2316.51900990570360
Pultruded 38×102428001450870550
Pultruded 50×1027.55540265014501000

At a 1 m span, 50×10 pultruded grating has about 4 times the capacity of 50 mm molded grating and 1.8 times that of 38×10 pultruded grating. More interestingly, its allowable load at a 1200 mm span equals the allowable load of the 38×10 model at 1000 mm. See the full tables in FRP grating load capacity tables, and the sister models in 38×10 pultruded grating, 38×23 pultruded grating and 25×15 pultruded grating.

Load design examples for pultruded composite grating

Example 1 — heavy equipment platform:1200 mm span, design uniform load 1000 kg/m².
  • Allowable load at L/200 = 1450 ≥ 1000 ✓; approximate deflection = 6 × 1000/1450 ≈ 4.1 mm.
  • Safety: 0.4 × 12430 ≈ 4970 ≫ 1000 ✓; the 38×10 model, at 870 at this span, is not sufficient.
Example 2 — long-span walkway:1400 mm span, uniform load 500 kg/m².
  • Allowable load at L/200 = 1000 ≥ 500 ✓; approximate deflection = 7 × 500/1000 = 3.5 mm < 6 ✓
  • Safety: 0.4 × 8900 = 3560 ≫ 500 ✓
Example 3 — trolley wheel:1000 mm span, concentrated load 300 kg.
  • Allowable concentrated load = 400 ≥ 300 ✓; approximate deflection = 5 × 300/400 ≈ 3.8 mm.
  • Safety: 0.4 × 7210 ≈ 2880 ≫ 300 ✓

50×10 or 38×10 pultruded grating?

Both models have a 25 mm pitch, a 10 mm opening and 38% open area; the only difference is the depth and thickness of the I-section. But that difference completely changes the structural behavior and the economics of the project:

Property50×1038×10Ratio
I-section50×15×4.538×15×4—
Weight (kg/m²)27.5241.15
Moment of inertia (mm⁴)4.71×10⁶1.9×10⁶2.5
Allowable uniform load at 1000 span265014501.8
Allowable concentrated load at 1000 span4002401.7
Capacity per weight at 1000 span96601.6
Maximum span for a 1000 kg/m² loadapprox. 1400 mmapprox. 1100 mm1.25
Engineering conclusion:Unlike the 38×23 versus 38×10 comparison, where structural efficiency was the same, the 50×10 model has about 60% more capacity per kilogram of material, because it places the material further from the neutral axis.
  • Choose 50×10 when the span is more than 1000 to 1100 mm, the design uniform load is above 1000 kg/m², or you want to reduce substructure steel by increasing beam spacing.
  • 38×10 is enough when the span is 1000 mm or less and floor height is limited; 12 mm less height is sometimes decisive when refurbishing existing platforms.

For example, on a 6 m platform with a 1000 kg/m² load, the 38×10 model, with a maximum span of about 1100 mm, needs 6 spans of 1000 mm (7 beams), whereas the 50×10 model works with 5 spans of 1200 mm (6 beams) — one fewer row of steel beams with its connections, painting and columns, plus a larger capacity reserve (1450 versus 1000 kg/m²).

Assembly sections for pultruded composite grating

The I-sections of pultruded composite grating are assembled with two types of cross member:

1) Assembly with a composite locking profile: a slotted pultruded profile is locked over the flanges of the I-sections and fixed with screws or pins; the top surface is even, and individual bars can be replaced locally.

2) Assembly with composite rods: FRP composite rods are passed through holes in the webs of the I-sections and fixed with epoxy adhesive. In the 50 mm section, the deeper web makes it easier to place the rod on the neutral axis, so drilling has the least effect on bending capacity.

Assembly of 50×10 pultruded grating with composite rods passing through the I-sections
Composite rods passing through the webs of the I-sections to assemble the panel.
Grid of I-sections and composite rods in 50 mm pultruded grating
Grid of load-bearing bars and transverse composite rods.
Sample panel of yellow pultruded composite grating with I-sections and cross rod
Sample of an assembled pultruded composite grating panel with composite cross rods.

Surface types of pultruded composite grating

Pultruded composite grating is produced with three surface types, chosen according to slip risk, the presence of oil and water, the slope of the route and the type of traffic. On slopes and in areas exposed to oil spills, high slip resistance is essential:

Pultruded grating surfaces: grooved, smooth and quartz-gritted
From right: grooved (anti-slip), smooth and gritted surfaces.
  • Grooved surface: longitudinal grooves formed on the top flange during production of the I-section prevent slipping; the standard option for platforms and walkways.
  • Smooth surface: a smooth, polished surface for special uses such as sports halls and hygienic areas. By turning the grating over, both surfaces can be used on the same project — for example the smooth face in an indoor equipment hall and the grooved face outdoors.
  • Gritted surface: a coating of quartz grit and sand of a defined grading bonded into a resin layer, increasing surface roughness for slopes, oily areas and wet routes and minimizing slip risk. For more roughness, the surface can also be sandblasted after production; sandblasting also gives a uniform roughness on a smooth surface.
Close-up of the grooved surface of pultruded composite grating I-sections
Close-up of the grooved surface on the flange of the I-sections.
Quartz gritted surface on pultruded composite grating
Gritted surface with quartz grit and sand to prevent slipping.

Applications of 50×10 pultruded grating

The composite surface is chosen to suit the environment of each application. Very high uniform and concentrated load capacity, long spans and a fine opening make these composite mesh panels suitable for heavy-duty uses where molded fiberglass grating is not adequate and metal grating corrodes:

  • Pump, compressor and heavy equipment platforms in petrochemical plants, refineries and power plants.
  • Covers for wide channels and basins in treatment plants with spans of 1200 to 1400 mm.
  • Floors for trolley, cart and light pallet-truck routes in corrosive environments.
  • Decks of jetties, footbridges and offshore platforms with high loads.
  • Cooling tower platforms, chlorination and acid units.
  • Refurbishing corroded steel platforms while keeping the existing substructure and long spans.
Limitation: the allowable concentrated load of this model at a 1000 mm span is about 400 kg; forklift or vehicle traffic on pultruded grating requires a dedicated design, short spans and approval by a structural engineer.
Moving a bundle of grey composite grating by forklift in the Nabak yard
Moving a bundle of grey composite grating by forklift at Nabak.
Loading a bundle of yellow composite grating onto a trailer by forklift at Nabak
Loading a bundle of yellow grating onto a trailer for shipment to a project.

Pultruded composite grating compared with metal grating

On long spans and in corrosive environments, 50×10 pultruded composite grating, with its long life and negligible maintenance, is a direct replacement for heavy steel grating:

Feature50×10 pultruded composite grating (FRP composite)Galvanized steel grating
Weightapprox. 27.5 kg/m²Far heavier for similar capacity
CorrosionNone; resistant to UV and chemicalsRusts once the zinc layer is damaged
Electrical conductivityFully insulatingConductive
Impact behaviorAbsorbs impact without permanent deformationPermanent denting
InstallationCut with simple tools; clips and bolted fixingsWelding and re-galvanizing of edges
Maintenance costVery lowPeriodic painting and repair

Ordering guide for pultruded grating

For an accurate price for 50×10 pultruded grating, prepare the following information; the span and type of loading are the most important inputs for choosing the model:

  1. Panel size: length in the direction of the load-bearing bars, and panel width
  2. Span and loading: support spacing and uniform or concentrated load
  3. Assembly type: locking profile or composite rod
  4. Surface type: grooved, smooth or gritted
  5. Resin and color: polyester, vinyl ester or fire-resistant grade
  6. Clips: type and number of grating clips and the substructure

Pultruded grating production and delivery at Nabak Composite

Nabak Composite produces, cuts and assembles 25, 38 and 50 mm composite I-sections and cross rods for pultruded grating on its own pultrusion lines, and packs and ships panels in custom sizes and various colors with grooved, smooth or gritted surfaces.

Glass roving bobbin creel on a Nabak pultrusion line
Roving bobbins — the source of the continuous longitudinal fibers in the I-sections.
Yellow pultruded profile leaving the puller of a Nabak production line
A yellow pultruded profile leaving the puller section of the production line.
Pallets of composite grating on a truck, ready to ship from the Nabak factory
Pallets of composite grating ready to ship from the Nabak factory.
Shipping yellow composite pultruded box profiles on a Nabak trailer
Shipping pultruded box profiles — composite substructure for grating platforms.
Nabak Composite showroom with grating and composite profiles
Nabak Composite product showroom.
25 mm pultruded grating15 mm and 25 mm openings for short spans.
38 mm pultruded grating10 mm and 23 mm openings for medium spans.
50 mm pultruded grating10 mm opening for long spans and heavy loads.
Clips and accessoriesStainless clips and composite substructure profiles.

Frequently asked questions about 50×10 pultruded grating

How much does 50×10 pultruded grating weigh?

The approximate weight of pultruded composite grating with a 50 mm height and a 10 mm opening is about 27.5 kg per m²; a 1×3 m panel weighs about 83 kg.

Up to what span is 50×10 pultruded grating suitable?

This model is designed for spans of 1200 to 1400 mm; its allowable uniform load at L/200 deflection is 1450 kg/m² at a 1200 mm span and 1000 kg/m² at 1400 mm.

Is 50×10 or 38×10 pultruded grating better?

For only about 15% more weight, the 50×10 model has about 1.8 times the allowable load of the 38×10 model, and its capacity per kilogram of weight is about 60% higher; for spans over 1000 mm or heavy loads, 50×10 is more economical because it allows wider beam spacing.

Is 50×10 pultruded grating suitable for forklift traffic?

The allowable concentrated load of this model at a 1000 mm span is about 400 kg, so it suits trolleys, carts and light pallet trucks, but forklift or vehicle traffic requires a special design and short spans.

What is the minimum seat length for 50×10 pultruded grating?

The minimum bearing length of pultruded grating on the supporting member is 25 mm, and the load-bearing I-sections must be perpendicular to the support beams.

Summary

50×10 pultruded composite grating — with 50×15×4.5 mm I-sections at 25 mm centers, 40 load-bearing bars per meter, 38% open area and a weight of about 27.5 kg/m² — is the highest-capacity pultruded grating from Nabak. A moment of inertia of 4.71×10⁶ mm⁴ allows an allowable uniform load of 2650 kg/m² at a 1 m span and 1000 kg/m² at 1400 mm. Per kilogram of material it has about 60% more capacity than the 38×10 model, and by allowing wider beam spacing it reduces substructure cost. Installed correctly (load-bearing bars perpendicular to the supports and a seat of at least 25 mm), with the right surface and the 40%-of-ultimate cap respected, this pultruded FRP grating is a light, insulating and durable alternative to heavy steel grating.

Nabak Composite

This article was prepared by the technical team of Nabak Composite, a manufacturer of pultruded grating and composite products.