NABAK Pultruded FRP Grating Engineering Catalog
کاتالوگ‌ها

NABAK Pultruded FRP Grating Engineering Catalog

PDF1.4 مگابایت1405/06/27English
مشاهده‌ی آنلاین سنددانلود فایل PDF
NABAK COMPOSITE · Technical Edition · 2026

Pultruded FRP Grating — Engineering Catalog

Design • Materials • Load & Deflection • Installation • Standards

01. Product Introduction

Pultruded FRP Grating for Industrial Infrastructure

NABAK COMPOSITE pultruded FRP grating is a structural flooring system made from glass-fiber-reinforced polymer profiles. Continuous pultrusion aligns the primary reinforcement along the load direction, while engineered I-shaped bearing bars provide high bending stiffness at low self-weight.

Unlike metallic grating, corrosion resistance is inherent to the composite system and is not dependent on a sacrificial coating. This helps reduce inspection, repainting and replacement requirements throughout the project life cycle.

Key propertyEngineering benefit
Low weightLower transport, lifting and installation demand; reduced dead load
Corrosion resistanceSuitable for wet and chemically aggressive environments
Electrical insulationImproved safety around electrical equipment
Slip resistanceConcave or grit surfaces help reduce slip risk
Long service lifeLower life-cycle maintenance requirements
Engineering note: Values and selections in this catalog are preliminary unless supported by the approved project data sheet, certified test report and responsible engineer’s calculations.

02. FRP Composite Technology

Fiber Reinforcement and Polymer Matrix

FRP combines a load-carrying fiber phase with a protective polymer matrix. E-glass fibers provide tensile and flexural capacity, stiffness and dimensional control. The resin transfers stress between fibers, protects them from moisture and chemicals, and defines the final environmental performance.

Resin systemTypical application
PolyesterGeneral industrial service
Vinyl EsterHighly corrosive, acidic and demanding chemical environments
PhenolicFire-sensitive applications requiring lower flame spread and smoke
EpoxySpecial engineered applications requiring high adhesion and performance

03. Product Definition

Structural Arrangement of Pultruded Grating

The panel consists of longitudinal load-bearing I-bars connected by transverse members. The bearing bars transfer bending actions to the supports; transverse bars maintain spacing, provide lateral stability and create an integrated panel.

Because the primary fibers are oriented along the profile length, pultruded grating is directionally optimized. Bearing-bar orientation must therefore be shown on project drawings and respected during installation.

Pultruded FRP grating panel with I-shaped bearing bars and transverse members
Pultruded FRP grating panel — I-bars and cross members

04. Manufacturing Process

Controlled Continuous Pultrusion

Pultrusion is a continuous manufacturing method that provides repeatable profile geometry and controlled fiber alignment.

StepProcess control
1. Fiber preparationE-glass rovings and mats are selected and arranged to the product design
2. Resin wet-outReinforcement is thoroughly impregnated with the specified resin system
3. Heated die formingThe composite enters a precision die and assumes its final section
4. Thermal curingThe thermoset resin cures under controlled temperature
5. Cutting and assemblyProfiles are cut, machined, connected and assembled into grating panels

05. I-Bar Engineering

How the Structural Section Carries Load

The flanges resist the principal bending stresses and increase the second moment of area. The web transfers shear and maintains the separation of the flanges. Under downward loading, the upper flange is predominantly in compression and the lower flange in tension.

Section height, flange geometry, web thickness, glass content and resin system all influence capacity and deflection. Final selection must be supported by project-specific load data.

06. Pultruded vs. Molded

Selecting the Appropriate FRP Grating Type

ParameterPultruded FRPMolded FRP
ManufacturingContinuous pultrusionOpen-mold molding
Primary structureI-shaped bearing profilesIntegral square mesh
Fiber directionLongitudinal and controlledMulti-directional
Flexural stiffnessHigh in bearing directionModerate and two-directional
Typical spanGenerally longerGenerally shorter
Cut-outsRequire engineering review and reinforcementMore tolerant of local openings
Typical useEngineered industrial structures and higher loadsGeneral flooring and complex cut-outs

07. Engineering Design Basis

Inputs Required Before Product Selection

A valid design starts with the clear span, load type, support arrangement, environmental exposure and serviceability criteria. The grating should not be selected from panel length and width alone.

Design inputRequired decision
Clear spanDetermines section height and stiffness demand
Distributed loadPersonnel, stored items and uniformly applied equipment loads
Concentrated loadWheels, legs, maintenance equipment and local impact
EnvironmentMoisture, chemicals, UV, salt water and operating temperature
ServiceabilityAllowable deflection, comfort and vibration
Safety factorsProject code, consequence of failure and uncertainty

08. Mechanical Calculations

Bending Stress and Section Capacity

Pultruded grating is analyzed as a system of parallel beams. Bending, shear, deflection and connection behavior must be checked for the governing load case.

The basic bending relationship is σ = M / Z, where σ is bending stress, M is bending moment and Z is section modulus. Calculated stress must remain below the project design resistance after all applicable reduction and safety factors.

09. Deflection Control

Serviceability and User Confidence

Strength alone is not sufficient. Deflection must be limited to maintain walking comfort, drainage geometry, equipment alignment and a visible sense of safety. For a simply supported member, deflection depends strongly on load, span, elastic modulus and second moment of area.

A project may specify a limit such as L/200. At a clear span of 2,000 mm, L/200 corresponds to 10 mm. The governing criterion must always come from the contract documents or responsible engineer.

10. Preliminary Load Guide

Typical Depth Selection for Early Design

The following heights are preliminary application guides only. Final selection requires verified span, bearing-bar spacing, load cases and allowable deflection.

Nominal depthPreliminary use
25 mmLight-duty walkways and general access
38 mmGeneral industrial floors and work platforms
50 mmIndustrial platforms, higher loading and longer spans

11. Physical Properties

Material Characteristics Relevant to Projects

PropertyTypical behavior
Density / self-weightSubstantially lower than steel grating
Water absorptionLow when correctly manufactured and sealed
Corrosion behaviorNo rusting; resin-dependent chemical resistance
Thermal conductivityLower than metals
Thermal expansionDirectional and generally lower than many plastics
UV resistanceCan be enhanced through additives and protective veil
Strength-to-weight ratioHigh
Magnetic behaviorNon-magnetic

12. Mechanical Properties

Typical Engineering Ranges

Values vary with profile geometry, glass content, test direction, resin system and production specification. Use certified project data for final calculations.

PropertyTypical range
Longitudinal tensile strength250–500 MPa
Flexural strength300–600 MPa
Longitudinal elastic modulus20–40 GPa
Shear strength50–100 MPa

13. Thermal Performance

Temperature Effects and Resin Selection

FRP does not conduct heat like metal, but strength and stiffness remain temperature-dependent. Continuous and peak temperatures, solar heating, thermal cycling and proximity to hot equipment must be stated during selection.

Polyester is suited to general service, Vinyl Ester to more demanding corrosive and thermal conditions, and Phenolic systems to special fire-sensitive applications. Project limits must be confirmed from the selected resin data sheet.

14. Chemical Resistance

Corrosion Performance Is Resin-Dependent

Chemical resistance is a primary reason for selecting FRP in oil and gas, petrochemical, water treatment and coastal facilities. Performance depends on chemical identity, concentration, temperature, exposure duration, immersion or splash conditions, cleaning practice and mechanical stress.

A written chemical-service review is required for aggressive or mixed exposures. “FRP” alone is not a complete chemical specification.

EnvironmentPreliminary resin direction
General industrial humidityPolyester or project-specified system
Acidic / highly corrosive dutyVinyl Ester
Fire-sensitive corrosive dutyPhenolic or qualified fire-retardant system
Marine and salt-water exposureCorrosion-resistant system with UV package

15. Electrical and Safety

Non-Conductive, Non-Magnetic Access Systems

FRP grating is electrically non-conductive under normal dry service and can improve safety around electrical installations. It is also non-magnetic and does not create the same spark concerns as ferrous grating.

Electrical behavior can change with contamination, moisture and conductive deposits. Site cleaning and the project electrical-risk assessment remain essential.

16. Anti-Slip Systems

Surface Options for Wet and Oily Areas

SurfaceUse
Grit TopMineral aggregate bonded to bearing-bar flanges for the highest traction
Concave / MeniscusTextured profile surface supporting drainage and regular access
Standard profileControlled dry environments where enhanced traction is not required
Grit-top anti-slip surface on pultruded FRP grating bars
Grit-top anti-slip surface

17. Fire Behavior

Resin Choice, Flame Spread and Smoke

FRP is an organic composite and does not behave like non-combustible steel. Fire performance must be specified using tested resin systems and the project’s fire strategy.

Phenolic resins can provide lower flame spread and smoke for demanding applications. Fire-retardant polyester or Vinyl Ester systems can improve performance for general industry. Industry data may classify qualified flame-retardant systems to ASTM E84 Class 1, with a flame-spread index of 25 or less; certification must match the supplied product.

18. Comparison with Galvanized Steel

Life-Cycle Selection in Corrosive Service

CriterionPultruded FRPGalvanized steel
Corrosion resistanceInherent and resin-dependentDependent on coating integrity
WeightLowHigh
Electrical conductivityNon-conductiveConductive
MaintenanceTypically lowInspection, coating repair and replacement may be required
FabricationDiamond tools and sealed cutsMetal cutting, welding and coating repair
Fire behaviorResin-dependentNon-combustible but strength falls at elevated temperature

19. Comparison with Stainless Steel

Technical and Commercial Trade-Offs

CriterionPultruded FRPStainless steel
Corrosion resistanceExcellent with correct resinExcellent with correct alloy
WeightLowHigh
Electrical / thermal conductionLow / non-conductiveHigh
Initial costProject-dependentOften high
Life-cycle costFavorable in many corrosive environmentsFavorable where alloy is correctly selected
Design behaviorAnisotropic compositeIsotropic metal

20. Product Configurations

NABAK COMPOSITE Supply Options

Product configuration is defined by section height, bearing-bar spacing, cross-rod system, panel size, resin, color, UV package and surface finish. Fabricated stair treads, platforms, covers and custom panels may be supplied to approved drawings.

Every quotation should state the bearing direction and the technical basis of selection.

21. Geometry and Dimensions

Dimensions That Control Structural Behavior

Panel length and width are fabrication dimensions; they do not by themselves establish capacity. Structural behavior is governed by clear span, bearing-bar height and thickness, bearing-bar spacing, transverse restraint and support bearing length.

Nominal depths commonly considered are 25, 38 and 50 mm. Actual geometry and tolerances must be confirmed on the project data sheet.

22. Engineering Selection Guide

A Practical Decision Sequence

Use the following sequence:

Project information→Load analysis→Support/span verification→Material and resin selection→Section selection→Deflection check→Connection detailing→Approval
Project conditionPriority
Chemical environmentConfirm chemical, concentration, temperature and resin
Marine exposureCorrosion-resistant resin plus UV provisions
Long span / higher loadIncrease section stiffness and verify deflection
Wet or oily floorSpecify Grit Top or qualified anti-slip surface
Electrical areaMaintain cleanliness and confirm site electrical requirements

23. Installation and Connections

Support, Fastening and Cut-Edge Practice

Panels must bear on a continuous, stable and correctly aligned support. Bearing direction must be perpendicular to the principal supports. Provide project-specified bearing length, edge clearance and expansion allowance.

Use compatible hold-down clips and corrosion-resistant fasteners. Prevent panel uplift, rocking and differential movement. Cut only with suitable diamond tooling, protect workers from dust and reseal exposed cut surfaces with a compatible resin.

24. Oil, Gas and Petrochemical

Typical High-Value Applications

Typical uses include access platforms, pipe-rack walkways, tank-area flooring, maintenance routes, trench covers and stairs. FRP can reduce corrosion-related maintenance in areas exposed to salt, humidity, process splash and chemical vapors.

The project review must still address fire zone, electrostatic requirements, concentrated maintenance loads, dropped-object risk and compatibility with the specific chemical inventory.

25. Power, Water and Wastewater

Wet-Service Infrastructure

Power facilities benefit from low weight and electrical insulation around selected equipment. Water and wastewater facilities benefit from resistance to continuous humidity, treatment chemicals and biological exposure.

Applications include channels, screens, clarifier access, pump-station floors, cable access routes, platforms and covers. Resin selection must reflect actual chemical dosing and temperature.

26. Quality Control

From Raw Materials to Finished Panel

Control stageKey checks
Raw materialsE-glass, resin, additives, UV and flame-retardant packages
Pultrusion processDie temperature, line speed, fiber/resin ratio and pulling stability
Profile inspectionDimensions, straightness, surface, cure and defects
Panel assemblySpacing, alignment, connections and squareness
Final releaseDimensions, appearance, marking, documents and project tests

27. Standards and Evaluation

Common Technical References

ReferenceUse
ASTM D790Flexural strength and modulus of plastics/composites
ASTM D638Tensile properties
EN 13706Specifications for pultruded profiles
ASTM E84Surface-burning characteristics
DIN 51130Slip resistance classification for floor surfaces
ASTM F1677Slip-resistance evaluation (legacy/reference use as specified)

28. Consolidated Datasheet

Typical Pultruded FRP Grating Data

ItemTypical / selectable value
MaterialE-glass reinforced thermoset polymer
Manufacturing methodPultrusion and panel assembly
ResinPolyester / Vinyl Ester / Phenolic / special system
Nominal depth25 / 38 / 50 mm
SurfaceStandard / Concave / Grit Top
ColorProject-selected; industrial yellow commonly supplied
UV performanceEnhanced with additives / veil as specified
Tensile strength250–500 MPa, longitudinal typical range
Flexural strength300–600 MPa, typical range
Elastic modulus20–40 GPa, longitudinal typical range
Shear strength50–100 MPa, typical range

29. Project Checklist

Information Required for Quotation and Approval

CategoryRequired information
GeometryInstallation area, clear span, panel size, support arrangement, bearing direction
LoadsDistributed load, concentrated load, wheel/footprint, impact and maintenance loads
EnvironmentChemical list, concentration, temperature, marine exposure, UV and immersion
PerformanceAllowable deflection, anti-slip need, fire requirement and electrical considerations
ProductDepth, resin, surface, color, fasteners, clips and fabrication drawings
DocumentationCalculations, test certificates, inspection plan and delivery marking

30. Engineering Conclusion

Specify a System, Not Only a Panel

Pultruded FRP grating is not merely a substitute for metal. It is an engineered structural system whose performance depends on the relationship between load, span, section geometry, fiber orientation, resin, environment, supports and connections.

NABAK COMPOSITE supports designers, consultants, contractors and asset owners with product selection, project-specific fabrication and technical documentation. Final structural acceptance remains with the responsible project engineer.

Engineering note: Values and selections in this catalog are preliminary unless supported by the approved project data sheet, certified test report and responsible engineer’s calculations.

HTML edition of the NABAK Composite Pultruded FRP Grating Engineering Catalog (33-page PDF, Technical Edition 2026). The original PDF remains available for download on this page.

‹ بازگشت به مرکز اسناد فنی