What is pultruded composite grating?
Pultruded composite grating is one type of composite mesh panel, made by laying composite I-sections (load-bearing bars) in parallel and tying them together with crossing composite rods. Both components are made by pultrusion: continuous roving and mat are pulled through a resin bath and shaped in a heated die, giving profiles with continuous longitudinal fibers. The I-sections are then drilled at precise intervals and assembled with the cross rods. On the market the product is also called pultruded FRP grating, pultruded GRP grating, pultruded GFRP grating and pultruded fiberglass grating; pultruded GRP and GFRP grating are simply pultruded composite grating made with glass fibers.
In the specification of pultruded composite grating, the designation "25×15" or "I25-15" gives two key properties: a grating height of 25 mm (the I-section depth) and a 15 mm opening (the clear gap between the flanges of two adjacent bars). This model is designed for walkways, platforms and channel covers where installation height is limited but high load capacity is required. For a comparison of molded, covered and pultruded grating, see the FRP grating buying and selection guide.
Specifications and dimensions of 25×15 pultruded grating
Main specifications of 25×15 pultruded composite grating at a glance:
The load-bearing bars of this grating are fiberglass I-sections measuring 25×15×4 mm (depth × flange width × thickness), assembled with transverse composite profiles. The I-sections are at 30 mm centers, so there are about 33 load-bearing bars per meter of grating width. Subtracting the 15 mm flange width from the 30 mm pitch gives a 15 mm opening, and the open area of the pultruded grating, allowing for the cross rods, is about 48 percent.
The 15 mm opening stops shoe heels from entering and small tools from falling through, while 48 percent open area is still enough for drainage, airflow and light.
| Property | Value | Description |
|---|---|---|
| Load-bearing bar section | I-section 25×15×4 mm | Pultruded fiberglass profile |
| Grating height | 25 mm | I-section depth |
| Grating opening | 15 mm | Clear gap between flanges |
| I-bar center-to-center | 30 mm | About 33 bars per meter |
| Open area of the pultruded grating | 48% | Drainage and airflow |
| Approximate weight | 14.5 kg/m² | About one third of steel grating of equal capacity |
| Standard resin | Isophthalic polyester | Vinyl ester and fire-retardant grades made to order |
Weight of pultruded composite grating
The approximate weight of 25×15 pultruded grating is 14.5 kg per m². This can be checked from the section properties: the cross-sectional area of the load-bearing bars per meter of width is 6.6×10³ mm²; with a density of about 1.9 g/cm³ for a pultruded profile, the bearing bars weigh about 12.5 kg/m², and the remaining 2 kg or so is the cross rods and fixings. A 1×3 m panel therefore weighs about 44 kg and two people can carry and install it.
Section properties of pultruded grating
The geometric properties of the composite section (cross-sectional area, section modulus and moment of inertia) are the basis for calculating stress and deflection of the grating. The values below are given per meter of width of the pultruded grating:
| Section property (per meter of width) | Value |
|---|---|
| Composite cross-sectional area | 6.6×10³ mm² |
| Section modulus S | 4.41×10⁴ mm³ |
| Moment of inertia I | 5.6×10⁵ mm⁴ |
Consistency check of section modulus and moment of inertia: for a symmetric section, S = I / (h/2) = 5.6×10⁵ / 12.5 ≈ 4.48×10⁴ mm³, which agrees with the table value (4.41×10⁴).
Because bending stiffness (E·I) increases with the cube of the height, 25 mm pultruded grating quickly reaches its deflection limit on long spans; for spans over 1200 mm or heavy loads, the 38 mm and 50 mm pultruded grating models are recommended.
Features of pultruded composite grating
The performance properties of pultruded composite grating make it a superior choice for corrosive and electrical environments:
How pultruded grating sits on its supports
In pultruded grating the main load is carried by the FRP I-bars, so the grating must be placed on the support seat with the load-bearing I-bars perpendicular to the support beams. Installing it the wrong way round (with the cross rods on the supports) drastically reduces capacity.
Installing fiberglass grating is straightforward: panels are fixed to the substructure beams with stainless steel grating clips (M-clips or saddle clips) so they do not shift under vibration or impact. Cut edges must also be sealed with resin (see cutting and machining composites).
Load capacity of pultruded composite grating
The loading of pultruded composite grating is assessed as concentrated load and uniform load, and for each one two criteria are defined: allowable load and ultimate load.
Basic definitions
- Concentrated load: the force is applied to the surface through a small area, such as a trolley wheel or an equipment leg.
- Uniform load: with a uniform (distributed) load, the force is spread evenly over the whole surface, such as a crowd of people.
- Allowable load based on deflection: the load that brings the mid-panel deflection to L/200 of the support spacing (span) — a deflection equal to 0.5 percent of the span.
- Ultimate load: the maximum load at which the grating panel will certainly break.
Load table for 25×15 pultruded grating
The pultruded composite grating load table below gives the allowable load at L/200 deflection and the ultimate load, for concentrated and uniform loading, at six common spans. The table has the same structure as the one for 25 mm molded grating, but the pultruded grating values are far higher:
| Support spacing (mm) | Concentrated load (kg) | Uniform load (kg/m²) | ||
|---|---|---|---|---|
| Allowable load at L/200 deflection | Ultimate load | Allowable load at L/200 deflection | Ultimate load | |
| 400 | 760 | 4,850 | 12,150 | 35,400 |
| 600 | 360 | 3,800 | 3,750 | 21,350 |
| 800 | 210 | 2,900 | 1,600 | 9,950 |
| 1,000 | 140 | 2,450 | 850 | 8,000 |
| 1,200 | 100 | 2,050 | 550 | 5,050 |
| 1,400 | 75 | 1,390 | 350 | 4,130 |
- At every span the deflection-based allowable load is below 40% of the ultimate load (for example at an 800 mm span: 1600 versus 3980), so deflection governs the design and the safety margin against failure is provided automatically.
- Doubling the span from 600 to 1200 mm reduces the allowable uniform load about 7 times (3750 to 550) — a sign of how strongly span affects deflection.
- At a 1400 mm span, L/200 deflection equals 7 mm; for a pedestrian route with a 6 mm limit, take about 86% of the allowable load (i.e. about 300 kg/m²).
Comparison with molded grating of the same height
| Grating type | 600 span | 800 span | 1000 span | 1200 span |
|---|---|---|---|---|
| Molded 25×38×38 | 476 | 201 | 103 | 60 |
| Molded 38×38×38 | 1700 | 750 | 400 | 250 |
| Pultruded 25×15 | 3750 | 1600 | 850 | 550 |
The table values are the allowable uniform load at L/200 deflection in kg/m². The 25 mm pultruded grating has more than twice the capacity of even the 38 mm molded grating; so in projects where installation height is limited (for example covering existing channels or refurbishing platforms), this model provides more capacity without changing the seat height. See the full tables for all types in FRP grating load capacity tables.
Load design examples for pultruded grating
- Allowable load at L/200 = 1600 ≥ 500 ✓; approximate deflection = 4 × 500/1600 ≈ 1.25 mm.
- Safety: 0.4 × 9950 = 3980 ≫ 500 ✓
- Allowable concentrated load at L/200 = 140 ≥ 100 ✓; approximate deflection = 5 × 100/140 ≈ 3.6 mm (below 6).
- Safety: 0.4 × 2450 = 980 ≫ 100 ✓
Assembly sections for pultruded composite grating
The load-bearing I-bars are tied together in two main ways:
1) Assembly with a composite locking profile: a pultruded profile with slots matching the I-bar flanges is locked over them. This gives a flatter top surface and a cleaner appearance.
2) Assembly with composite rods: FRP rods are passed through holes in the webs of the I-bars and fixed with epoxy adhesive. This gives a strong joint and better load sharing between bars.
In both methods the cross members are usually spaced about 150 to 200 mm apart; their job is to keep the I-bars precisely spaced and to spread concentrated loads over several load-bearing bars.
Surface types of pultruded composite grating
The surface of pultruded grating is chosen according to the slip risk of the environment. The three main surface types are:
Grooved surface (anti-slip): longitudinal grooves are formed on one face of the I-bars during production to prevent slipping; the most common option for walkways and platforms.
Smooth surface: on smooth-surface grating the top is completely smooth and polished, for special uses such as sports halls and areas where easy cleaning or smooth wheeled traffic matters. By turning the grating over, both the grooved and the smooth face can be used.
Gritted surface: on slopes, oil-contaminated areas and high-risk routes, the surface is coated with quartz grit and sand of a specific grading; how deeply the grit is embedded in the resin determines how long the roughness lasts, maximizing roughness and slip resistance. To increase roughness, the surface can also be sandblasted after production; sandblasting gives a uniform roughness on a smooth surface.
Applications of 25×15 pultruded grating
Because of its low height and high load capacity, 25×15 pultruded composite grating is widely used for the walking surfaces below. Compared with molded fiberglass grating, this model is the better choice for longer spans:
- Walkways and pedestrian platforms in treatment plants, petrochemical plants and power plants with spans up to about 1 m.
- Cable and sewage channel covers with limited seat height.
- Access platform floors and landings of composite stairs.
- Replacing corroded steel grating without changing the seat height.
- Car wash floors, sports halls and wet environments.
- Electrical equipment platforms that need an insulating composite floor.
- Decks of light jetties and coastal composite structures.
- Short composite footbridges with a composite profile substructure.
Pultruded composite grating compared with metal grating
Pultruded composite grating replaces galvanized steel grating in many projects. Unlike metal grating, pultruded composite panels do not corrode in wet and chemical environments and need no periodic painting or maintenance:
| Feature | 25×15 pultruded composite grating | Galvanized steel grating |
|---|---|---|
| Weight | approx. 14.5 kg/m² | About three times as heavy |
| Corrosion | None; UV resistant with UV additive | Rusts once the zinc layer is damaged |
| Electrical conductivity | Fully insulating | Conductive |
| Impact behavior | Absorbs impact without permanent deformation | Permanent denting |
| Installation and cutting | Simple tools, no welding; clips and bolted fixings | Welding and re-galvanizing of edges |
| Slip | Grooved or gritted anti-slip surface | Serrated; slippery when oily |
Alongside these advantages, the lower elastic modulus of composite means the loading of pultruded grating is always governed by deflection — which is accounted for in the load table above.
Ordering guide for pultruded grating
To order pultruded composite grating accurately, give the Nabak team the following information:
- Panel size: length in the direction of the load-bearing bars, and width
- Span and loading: support spacing, uniform or concentrated load
- Assembly type: locking profile or composite rod
- Surface type: grooved, smooth or gritted
- Resin and color: polyester, vinyl ester or fire-retardant
- Clips and fixings: type and number of grating clips
Pultruded grating production at Nabak Composite
Nabak Composite produces and assembles the composite I-bars and cross rods of pultruded composite grating on its own pultrusion lines, and supplies panels in custom sizes and various colors, with grooved, smooth or gritted surfaces and polyester, vinyl ester or fire-retardant resins.
Frequently asked questions about 25×15 pultruded grating
How much does 25×15 pultruded grating weigh?
The approximate weight of pultruded composite grating with a 25 mm height and a 15 mm opening is about 14.5 kg per m² — about one third of steel grating of similar capacity.
What span is 25×15 pultruded grating suitable for?
For walkways and pedestrian platforms with a load of about 500 kg/m², this grating is suitable up to a span of about 1000 to 1200 mm with deflection below L/200; the allowable uniform load is about 850 kg/m² at a 1000 mm span and about 550 kg/m² at 1200 mm.
What is the difference between pultruded and molded grating?
Pultruded grating is assembled from pultruded I-sections and cross rods, with its fibers concentrated along the load-bearing bars; that is why, at the same 25 mm height, its allowable load at a 1 m span is about eight times that of molded grating. Molded grating is one-piece and bidirectional, and has greater chemical resistance.
What is the minimum seat length for pultruded grating?
The minimum bearing length of pultruded grating on the supporting member is 25 mm, and the load-bearing I-bars must be perpendicular to the support beams.
What surfaces does pultruded grating come with?
Pultruded grating is produced with three surface types: a grooved anti-slip surface, a smooth surface for uses such as sports halls, and a quartz-gritted surface for slopes and oily areas.
Summary
At a glance, 25×15 pultruded composite grating — with 25×15×4 mm I-sections at 30 mm centers, 48% open area and a weight of about 14.5 kg/m² — is the lightest, lowest-profile pultruded grating, with a capacity beyond that of 38 mm molded grating. Its allowable uniform load ranges from 12,150 kg/m² at a 400 mm span to 350 kg/m² at 1400 mm, and deflection governs the design. Installed correctly (load-bearing bars perpendicular to the supports and a seat of at least 25 mm), with the right surface and the 40%-of-ultimate cap respected, this pultruded FRP grating is a light, safe and durable solution for walkways, platforms and channels.
This article was prepared by the technical team of Nabak Composite, a manufacturer of pultruded grating and composite products.