FRP/GFRP Covered Grating (Composite Checker Plate) – Technical Datasheet | Nabak Composite
دیتاشیت محصولات

FRP/GFRP Covered Grating (Composite Checker Plate) – Technical Datasheet | Nabak Composite

مقاله1405/08/12English
مشاهده‌ی آنلاین سند
NABAK
COMPOSITE
Nabak Sazeh Gostar
ENGINEERING COMPOSITES
TECHNICAL DATA SHEETSpecifications & Selection Guide

Covered Composite Grating
(Composite Checker Plate)

FRP / GFRP COVERED GRATING

FRP covered composite grating with a checker-plate surface on an industrial structure - Nabak Composite
PRODUCT SERIESCOVERED GRATING
Technical SpecificationsDimension TablesInstallation Details
NBK-TDS-CGR-01-ENREV 1.0   |   2026
NABAK COMPOSITE◉   nabakcomposite.com☎   +98 21 4881 2124Nabak Sazeh Gostar
NABAK
COMPOSITE
FRP / GFRP Covered Grating – Technical DatasheetIntroduction, Structure & Advantages  |  Page 1 of 5

Covered composite grating by Nabak Composite (composite checker plate) is made from a molded FRP grating or a pultruded FRP grating and a GFRP cover plate with a checker or grit surface; it is a completely closed, slip-resistant, corrosion-proof and electrically insulating flooring that replaces steel checker plate and galvanized tread plate.

0%open area; fully closed surface
3–6 mmGFRP cover plate thickness
≈ 2×increase in bending stiffness
R10–R13slip-resistance class, DIN 51130

What Is Covered Composite Grating (Covered FRP Grating)?

Covered composite grating, also known as covered FRP grating, covered GFRP grating, solid-top grating and composite checker plate, is a composite sandwich structure. Its core is an FRP composite grating that carries the load to the supports, and its top face is a continuous GFRP composite plate that completely closes the walking surface. The cover plate is joined to the composite grating in one of two ways: integral molding, in which the plate and the FRP grating are fused in a single cure cycle, or bonding with a structural resin (epoxy or vinyl ester) under pressure and controlled curing.

In this structure the cover plate sits above the neutral axis and acts like the compression flange of a beam; for this reason, besides closing the surface, covered composite grating significantly increases the bending stiffness and the concentrated-load capacity of the FRP grating. FRP (fiber-reinforced polymer) is the generic name for polymers reinforced with fibers, and GFRP is the type of FRP composite reinforced with glass fiber; all components of Nabak Composite covered grating are made of GFRP composite.

Layer Structure of Covered Composite Grating

Slip-resistant surfaceChecker-plate pattern or quartz / silica grit in the surface resin of the composite
GFRP cover plate3 to 6 mm composite sheet with glass fibers and the same resin family as the FRP grating
Bonding layerIntegral molded bond or structural resin adhesive between the plate and the grating
FRP grating coreMolded composite grating or pultruded composite grating; the main load-bearing member

Advantages of Covered FRP Grating

  • Fully closed surface: prevents bolts, nuts, tools and small objects from falling through, and stops shoe heels and trolley wheels from sinking in.
  • Better distribution of concentrated loads: the composite cover plate spreads the load across several bearing bars of the GFRP grating.
  • Control of odor, gas and splash: suitable for covering channels, trenches and wastewater tanks.
  • Corrosion-proof: unlike steel checker plate, composite checker plate does not rust and needs no painting.
  • Slip resistance in the presence of water and oil: the grit surface of covered grating can be produced up to class R13.
  • Electrically insulating and non-magnetic: suitable for covering cable trenches in electrical substations.
  • Light weight: the density of GFRP composite is about one quarter that of steel; hatches can be lifted by hand.
  • Easy, hygienic cleaning: suitable for food and pharmaceutical industries and public spaces.

When should covered composite grating be chosen? Wherever the walking surface must be completely closed (risk of parts falling on people or equipment below), traffic includes high-heeled shoes, wheelchairs or trolleys, or control of odor, splash and dust matters, covered FRP grating is a better replacement for open composite grating. If fast water drainage, light transmission and ventilation are the priority, open GFRP grating is recommended.

Covered composite grating | FRP checker plate | Covered GFRP gratingnabakcomposite.com  |  +98 21 4881 2124
NABAK
COMPOSITE
FRP / GFRP Covered Grating – Technical DatasheetDimension Tables, Weights & Surface Types  |  Page 2 of 5

Dimension Table of Covered Molded Composite Grating

Table 1 — Common dimensions and weights of covered FRP grating with a molded core
Grating height (mm)Mesh (mm)Cover plate thickness (mm)Total height (mm)Approx. weight (kg/m²)Common panel size (mm)
2538 × 3832817 – 191000×4000 / 1220×3660
3038 × 3833319.5 – 211000×4000 / 1220×3660
3838 × 3834124 – 261000×4000 / 1220×3660
3838 × 3854328 – 301000×4000 / 1220×3660
5050 × 5055532 – 351000×4000 / 1220×3660

Dimension Table of Covered Pultruded Composite Grating

Table 2 — Covered GFRP grating with a pultruded core (I-Bar)
Bearing profileGrating height (mm)Cover plate (mm)Total height (mm)Approx. weight (kg/m²)Main application
Light I-Bar2532818 – 21Walkways and pedestrian platforms
Standard I-Bar3834122 – 26Long spans, trench covers
Standard I-Bar3854326 – 30Light trolleys and hand carts
Heavy I-Bar5065632 – 36Heavier concentrated loads

Dimensions are based on common sizes of covered composite grating in the FRP industry. Custom cutting, drilling and hatch fabrication from covered GFRP grating are possible. Common tolerances: height ±1 mm, length and width ±3 mm.

Surface Types and Cover Plates of Composite Checker Plate

Table 3 — Surface options of covered FRP grating
Surface typeCommon thickness (mm)Plate weight (kg/m²)Approx. slip classRecommended use
Checker plate (Checker / Diamond)3 – 55.5 – 9.5R10 – R11Platforms, walkways, stairs, easy cleaning
Fine grit3 – 56 – 10R11 – R12Wet environments, food industry
Coarse grit3 – 66.5 – 11.5R12 – R13Oily surfaces, slopes, offshore platforms
Smooth3 – 55.5 – 9.5R9Clean rooms, non-walking covers

Common colors of covered composite grating are gray, safety yellow, green and black; a yellow core with a gray top is very common for making edges visible. The pigment is dispersed through the full thickness of the FRP composite, and UV-resistant additives increase the color stability of FRP checker plate outdoors.

Applications of Covered Composite Grating

Trench and channel coversSubstation cable channels, sewage and surface-water channels with FRP checker plate
Industrial platforms and walkwaysRefineries and petrochemical plants, where falling tools and parts are dangerous
Water and wastewater treatment plantsCovering basins and tanks for odor control with covered GFRP grating
Food and pharmaceutical industriesHygienic, rust-free and washable composite flooring
Marine and jettiesDecks, access bridges and slip-resistant waterfront platforms
Public spacesPedestrian bridges, parking floors and routes with high-heel and wheelchair traffic
Composite checker plate | Solid-top grating | Slip-resistant composite flooringnabakcomposite.com  |  +98 21 4881 2124
NABAK
COMPOSITE
FRP / GFRP Covered Grating – Technical DatasheetMechanical & Physical Properties, Slip Resistance and Fire  |  Page 3 of 5

Mechanical Properties of Covered GFRP Grating Components

Table 4 — Reference mechanical properties of FRP composite in covered grating
PropertyTest standardUnitGFRP cover plateMolded corePultruded core (longitudinal)
Glass fiber content by weightASTM D2584%25 – 3530 – 3560 – 70
Tensile strengthASTM D638MPa80 – 13090 – 140200 – 350
Flexural strengthASTM D790MPa130 – 200140 – 200200 – 350
Flexural modulusASTM D790GPa7 – 108 – 1217 – 25
Compressive strengthASTM D695MPa120 – 160120 – 170200 – 300
Shear strength of the plate-to-grating bondASTM D5868MPa≥ 5 – 10 (structural adhesive) / integral in a molded bond
Barcol hardnessASTM D2583—35 – 4535 – 4540 – 50

Comparison of Covered Composite Grating with Other Options

Table 5 — Covered FRP grating versus open FRP grating and steel checker plate
PropertyCovered GFRP gratingOpen FRP gratingSteel checker plate
Material density (g/cm³)1.7 – 2.01.7 – 2.07.85
Open area0%65 – 70%0%
Prevention of small objects falling throughCompleteNoneComplete
Water drainage and passage of light and airNone (slope required)CompleteNone
Concentrated-load distributionExcellentMediumExcellent
Corrosion resistanceExcellentExcellentPoor (needs paint)
Electrical conductivity / sparkingNoneNoneYes
Coefficient of thermal expansion (10⁻⁶ /°C)15 – 2515 – 2512
Thermal conductivity (W/m·K)0.2 – 0.40.2 – 0.4≈ 50
24-hour water absorption (ASTM D570)0.1 – 0.5%0.1 – 0.5%—
Table 6 — Slip-resistance classification (DIN 51130)
ClassAcceptance angleRecommended surface
R96° – 10°Smooth
R1010° – 19°Checker plate
R1119° – 27°Checker plate / fine grit
R1227° – 35°Fine / coarse grit
R13> 35°Coarse grit
Table 7 — Reference fire indices
TestStandardFlame-retardant resin
Flame spreadASTM E84≤ 25 (Class 1)
Smoke developmentASTM E84≤ 450
Extinguishing behaviorASTM D635Self-extinguishing
Oxygen indexASTM D2863≥ 30%
Surface spread of flameBS 476-7Class 1

The values in Tables 4 to 7 are common reference ranges in FRP and GFRP composite technical literature and are not Nabak Composite's own laboratory results; for design, the test results of each covered grating order govern.

Surface selection note: For dry, indoor platforms, raised-pattern composite checker plate is sufficient and is easier to clean. For oily environments, slopes, stairs and offshore platforms, covered GFRP grating with a coarse grit surface (R12 to R13) is recommended. In tunnels and enclosed spaces with low-smoke requirements, phenolic resin should be selected for the FRP composite.

Covered grating specifications | GFRP composite | Slip-resistant FRP checker platenabakcomposite.com  |  +98 21 4881 2124
NABAK
COMPOSITE
FRP / GFRP Covered Grating – Technical DatasheetResins, Chemical Resistance & Section Formulas  |  Page 4 of 5

Resins and Chemical Resistance of Covered Composite Grating

Table 8 — Resin selection for covered FRP grating and general guide to chemical resistance (ambient temperature)
Resin typeApprox. service temperatureHCl 10%NaOH 10%SeawaterHypochlorite 5%Recommended use
Orthophthalic polyester60 °CLimitedNot suitableGoodNot suitableGeneral, low-corrosive
Isophthalic polyester70 – 80 °CGoodLimitedExcellentLimitedWater and wastewater, marine
Vinyl ester90 – 105 °CExcellentExcellentExcellentExcellentPetrochemical, chemical
Phenolic120 – 150 °CGoodLimitedExcellentLimitedMarine, tunnels, low smoke

In covered composite grating, the resin of the cover plate, the resin of the FRP grating core and the bonding adhesive resin must be selected from the same family with matching chemical resistance.

Weight and Material Formulas for the Composite

1. Areal weight of the GFRP cover plate
wp = ρp · tp

ρp in g/cm³ and tp in mm, result in kg/m². Example: 1.85 × 3 = 5.55 kg/m²

2. Total weight of the covered grating panel
W = (wg + wp) · A

Example: 38 mm FRP grating (≈ 19 kg/m²) + 3 mm plate, 1000×4000 panel: (19 + 5.55) × 4 ≈ 98 kg

3. Density of GFRP composite (rule of mixtures)
Vf = Wf / ρfWf / ρf + (1 − Wf) / ρm ,   ρc = Vf ρf + (1 − Vf) ρm

ρf ≈ 2.55 g/cm³ (E-glass), ρm ≈ 1.15 g/cm³ (resin). Mineral and flame-retardant fillers bring the density of the composite cover plate to about 1.8 to 1.9.

Composite Section Formulas for Covered FRP Grating

4. Neutral-axis location and moment of inertia of the composite section (parallel-axis theorem)
ȳ = Σ Ai yiΣ Ai     I = Σ ( Ii + Ai di² )

Ai area of each component (grating bars and cover plate), yi distance of its centroid from the bottom, di = |yi − ȳ|

Example — 1 m width of 38 mm molded grating (26 bars of 6 mm) + 3 mm cover plate, assuming full composite action: Grating: A = 26×6×38 = 5928 mm², I = 26×6×38³/12 ≈ 7.13×10⁵ mm⁴, y = 19 mm Plate: A = 1000×3 = 3000 mm², I = 1000×3³/12 = 2250 mm⁴, y = 39.5 mm ȳ = (5928×19 + 3000×39.5) / 8928 ≈ 25.9 mm  →  I ≈ 1.55×10⁶ mm⁴ ≈ 2.18 × Iopen That is, in this simple model the composite cover plate roughly doubles the bending stiffness of the GFRP grating (the transverse bars are neglected).
5. Shear flow and shear stress in the plate-to-grating bond line
q = V QI ,   Q = Ap dp ,   τ = qbbond

The example above with a 5 kPa load and a 1000 mm span: V = 2500 N, Q = 3000 × 13.6 ≈ 40 800 mm³, q ≈ 66 N/mm; with a contact width b ≈ 169 mm → τ ≈ 0.39 MPa, far below the shear strength of the structural adhesive.

FRP covered grating | Vinyl ester grating | FRP and GFRP compositenabakcomposite.com  |  +98 21 4881 2124
NABAK
COMPOSITE
FRP / GFRP Covered Grating – Technical DatasheetLoading, Selection Guide & Installation Details  |  Page 5 of 5

Loading Formulas for Covered Composite Grating

6. Deflection under uniform load and deflection ratio
δ = 5 w L⁴384 E I ,   δcovδopen = IopenIcov

In the example of formula 4: δcov / δopen ≈ 1 / 2.18 ≈ 0.46; deflection reduced by about 54%

7. Mid-span deflection under a concentrated load
δ = P L³48 E I

P concentrated load (a pedestrian is typically 1.5 kN over 100×100 mm). Common deflection limit L/200 or 6.35 mm

8. Spread of the concentrated load and number of bars engaged
beff = b0 + 2tp ,   n ≈ beffp + 1

b₀ width of the load footprint, tp plate thickness, p bar pitch. Example: 100 + 6 = 106 mm, p = 38 → n ≈ 3.8 bars; a shoe heel never sinks into the mesh.

9. Contact pressure of a trolley wheel
pc = PAc

Example: a 2 kN wheel with a 50×20 mm contact area → pc = 2000 / 1000 = 2 MPa; below the compressive strength of the GFRP plate

10. Friction coefficient in the inclined-plane test
μ = tan α

α is the DIN 51130 acceptance angle. Example: R11 with α = 19° → μ ≈ 0.34 and R13 with α = 35° → μ ≈ 0.70

11. Thermal expansion and life-cycle cost
ΔL = α L ΔT ,   LCC = C0 + Σ Cm,t(1+r)t

4000 mm panel, α = 20×10⁻⁶, ΔT = 40 °C → ΔL = 3.2 mm. The maintenance cost of FRP checker plate is almost zero.

Table 9 — Preliminary span guide for covered composite grating (pedestrian load ≈ 5 kPa)
FRP grating coreTotal height (mm)Approx. recommended span (mm)Application
Molded 25 + plate 328up to ≈ 700Light channel and trench covers
Molded 30 + plate 333up to ≈ 900Public walkways
Molded 38 + plate 3 / 541 / 43up to ≈ 1100 – 1200Industrial platforms, stairs
Molded 50 + plate 555up to ≈ 1500High-traffic platforms
Pultruded 38 + plate 341up to ≈ 1700Long spans

Preliminary guide based on common FRP grating industry practice; the final span should be checked with formulas 4 to 8 and the product load table. Covered grating requires a special design for vehicle traffic.

Installation Details of Covered FRP Grating

Covered composite grating panels are fastened to the structure with countersunk screws or stainless steel screws and washers through the plate, or with M and J clips to the supporting beam; at least 4 fixing points per panel and a bearing length of at least 25 mm are recommended. Because the open area is zero, provide a 1 to 2 percent slope or a side drain for water drainage, and consider ventilation under the cover in channels carrying gas. Leave a 3 to 5 mm joint between panels for thermal expansion. Cutting and drilling of composite checker plate is done with a diamond blade, and the edges are sealed with resin. The low weight of the panels makes fast and easy installation possible. In highly corrosive environments or where electrical insulation is required, composite bolts, nuts and washers can be used instead of metal screws; for edge safety of platforms and stairs, covered grating is installed together with composite handrails.

What is covered composite grating?

Covered composite grating is an FRP or GFRP grating topped with a 3 to 6 mm composite plate with a checker-plate or grit surface, bonded or integrally molded, to create a completely closed, slip-resistant surface.

What is the difference between covered grating and ordinary composite grating?

Ordinary composite grating has about 65 to 70 percent open area, while covered grating has zero open area; it blocks small objects, shoe heels, liquids and odors, spreads concentrated loads better and has higher bending stiffness.

What advantage does composite checker plate have over steel checker plate?

FRP composite checker plate does not rust, is not electrically conductive, has about one quarter of the density of steel and needs no painting, and its surface is less slippery when water and oil are present.

What is the slip-resistance class of the covered composite grating surface?

The approximate slip-resistance class (DIN 51130) depends on the surface: checker-plate pattern R10 to R11, fine grit R11 to R12, coarse grit R12 to R13 and smooth surface R9. For oily environments, slopes and offshore platforms, a coarse grit surface is recommended.

How is covered composite grating installed?

Panels are fastened to the structure with countersunk screws or stainless steel screws and washers through the plate, or with M and J clips to the supporting beam; at least 4 fixing points per panel and a bearing length of at least 25 mm are recommended. Because the open area is zero, a 1 to 2 percent slope or a side drain is provided for water drainage, and a 3 to 5 mm joint is left between panels for thermal expansion.

Is covered composite grating suitable for vehicle traffic?

Covered grating requires a special design for vehicle traffic, and the final span must be checked with the composite-section formulas and the product load table. For light trolleys and hand carts, a standard I-Bar pultruded core with a 5 mm plate is suggested, and for heavier concentrated loads, a heavy I-Bar core with a 6 mm plate.

Request a quote for covered composite grating: state the grating height, core type (molded / pultruded), plate thickness and surface type, resin, color, panel size and environmental conditions.
Nabak Sazeh Gostar  |  nabakcomposite.com  |  +98 21 4881 2124

Disclaimer: the information in this datasheet is prepared from general and common data of the FRP and GFRP composite industry and is provided for guidance. Nabak Composite reserves the right to modify the technical specifications of covered composite grating without prior notice.

© Nabak Composite — FRP and GFRP covered composite gratingnabakcomposite.com  |  +98 21 4881 2124
‹ بازگشت به مرکز اسناد فنی