TECHNICAL DATA SHEET

FRP/GFRP Composite Flooring & Decking

Panel dimensions, surface finishes, mechanical properties, and span & deflection tables for pultruded GFRP decking

NBK-TDS-FLR-02-ENRev 1.0  ·  2026
FRP/GFRP Composite Flooring – Technical DatasheetIntroduction, Structure & Benefits  |  Page 1 of 5

Nabak Composite FRP flooring (FRP / GRP Flooring) is a hollow pultruded GFRP composite deck panel that forms a closed, flat, seamless surface through its integral top skin, longitudinal webs and tongue-and-groove edge. It is a lightweight, corrosion-proof, rot-proof, paint-free replacement for timber decking, wood-plastic composite (WPC) decking, steel checker plate and concrete slabs on pedestrian bridges, balconies, terraces, piers and industrial platforms.

300 / 500 mmeffective panel width
≈ 10–12.5 kg/m²FRP flooring surface weight
≤ 1550 mmspan between support beams
≤ 12 mcontinuous pultruded panel length

What Is FRP Composite Flooring (GFRP Composite Decking)?

Composite flooring — also known as FRP flooring, GFRP flooring, composite decking, composite deck panel, fiberglass flooring or FRP decking — is manufactured by pultrusion: continuous glass-fiber rovings, together with transverse mats and fabrics, pass through a resin bath and are cured to final shape in a heated die. The cross-section of a Nabak composite flooring panel consists of a top skin, two or three longitudinal webs with feet, and a hooked tongue-and-groove edge that locks into the adjoining panel's groove.

FRP is the general name for fiber-reinforced polymers, and GFRP (or GRP) is the FRP composite reinforced with glass fiber — see our FRP vs. GRP comparison for details. Unlike WPC decking, which is made from wood flour and plastic, FRP composite flooring is reinforced with continuous glass fiber and has structural-grade stiffness and strength; this is why GFRP deck panels can span widely spaced steel beams and act directly as a load-bearing deck, with no timber sub-framing or base sheet required.

Cross-Section of a Composite Flooring Panel

Decorative, anti-slip top layerWood-grain film, grey pigment, or a grit-coated surface with a UV-resistant polyurethane topcoat.
GFRP top skinA 4–5 mm pultruded composite skin that transfers wheel and foot loads to the webs.
Longitudinal websTwo or three 4–4.5 mm webs with feet — the main flexural and shear-carrying members of the FRP flooring panel.
Tongue-and-groove edgeA hook-and-groove longitudinal joint that locks panels together, aligns the surface and conceals fasteners.

Benefits of FRP Flooring

  • Corrosion and rot resistant: composite flooring does not rust, rot or swell in seawater, rain, de-icing salt or general moisture.
  • Lightweight yet structural: surface weight of roughly 10–12.5 kg/m² — about one-twentieth of a 10 cm concrete slab and one-quarter of a 6 mm steel checker plate.
  • Fast installation: GFRP deck panels up to 12 m long, with tongue-and-groove joints and stainless screws, can be installed in a matter of hours.
  • Virtually maintenance-free: FRP flooring needs no paint, oiling or sanding, giving it a very low life-cycle cost.
  • Slip-resistant and safe: a grooved or grit-coated surface, with no cracking, splintering or flaking as wood does over time.
  • Wood look, composite durability: the wood-grain top layer brings the warm appearance of timber together with the service life of GFRP composite.

Nabak Composite Flooring Range

Wood-grain flooringGFRP deck panel with a gloss or matte wood-grain film for balconies, terraces and pedestrian bridges
Industrial grey flooringGrooved FRP flooring for platforms, rooftops and service walkways
Grit-coated anti-slip flooringComposite decking with a quartz-grit surface for piers, pools and ramps
composite flooring | FRP flooring | GFRP composite deckingnabakcomposite.com  |  +98 21 4881 2124  |  @nabak.composite
FRP/GFRP Composite Flooring – Technical DatasheetDimensions, Finishes & Surface Options  |  Page 2 of 5

Cross-Section Dimensions and Properties

Table 1 — Common pultruded FRP flooring profiles (ρ = 1.85 g/cm³)
Panel codeEffective width × height (mm)Skin / web (mm)Web countCross-section area (mm²)Moment of inertia I (mm⁴)Weight (kg/m)Surface weight (kg/m²)
NBK-FD 300/40300 × 404 / 4216162.47×10⁵2.9910.0
NBK-FD 300/50300 × 505 / 4.5220604.97×10⁵3.8112.7
NBK-FD 500/40500 × 404 / 4326243.79×10⁵4.859.7
NBK-FD 500/50500 × 505 / 4.5333407.62×10⁵6.1812.4

Panel codes are indicative. Section properties are calculated with a simplified model (skin, webs and feet; excluding the hook edge) using the formulas on page 4; actual section dimensions may vary slightly per order. Standard composite flooring panel lengths: 3000, 6000 and up to 12 000 mm. Typical tolerances: wall thickness ±0.3 mm, height ±0.5 mm.

FRP Composite Flooring Surface Finishes

Table 2 — Surface and color options for GFRP deck panels
Finish typeProduction methodApprox. slip resistanceRecommended use
Gloss wood grain (walnut, teak, pine)In-mold wood-grain film + polyurethane coatingR10 (with longitudinal groove)Balconies, terraces, villas, architectural areas
Matte wood grainWood-grain film + matte topcoatR10 – R11Pedestrian bridges, parks, walkways
Grooved greyPigment in resin + longitudinal grooveR10 – R11Industrial platforms, rooftops, corridors
Grit-coatedQuartz grit broadcast in the surface resinR12 – R13Piers, ramps, pools, oily surfaces

Pigment is dispersed through the full resin thickness, and the wood-grain layer is protected by a UV-resistant aliphatic polyurethane topcoat; unlike timber, FRP flooring does not crack, grey out or flake in sunlight and needs no periodic oiling or painting.

Applications of Composite Flooring

Pedestrian bridgesLightweight deck for pedestrian bridges on steel girders, using wood-grain FRP flooring
Balconies and terracesWaterproof, maintenance-free composite flooring for buildings and villas
Piers and marinasGFRP composite decking resistant to seawater and rot
Rooftops and service walkwaysClosed walking surfaces on roofs and plant areas with FRP deck panels
Industrial platforms and treatment plantsClosed, corrosion-proof decking for platforms and channel covers
Pools, parks and public areasSlip-resistant fiberglass flooring around pools and along walkways

Accessories for the FRP Flooring System

Table 3 — Fittings and accessories for composite flooring
ComponentMaterialFunction
End capColor-matched composite / PVCCloses panel cavity ends and keeps out water and insects
Start/end edge trimGFRP angle or channelCovers the free edge of the first and last flooring panel
Self-tapping screw or bolt & nutStainless steel 304 / 316Fastens the panel to the steel beam through the web foot or hook edge
Hidden clipStainless steelFastener-free connection for architectural wood-grain flooring
Rubber strip under panelEPDMEliminates noise and vibration on steel beams and absorbs surface irregularities
composite deck panel | FRP wood-grain flooring | GFRP deckingnabakcomposite.com  |  +98 21 4881 2124  |  @nabak.composite
FRP/GFRP Composite Flooring – Technical DatasheetMechanical & Physical Properties, Comparison  |  Page 3 of 5

Mechanical and Physical Properties of Pultruded FRP Flooring

Table 4 — Reference properties of pultruded GFRP composite used in Nabak flooring panels
PropertyTest standardUnitLengthwise (LW)Crosswise (CW)
Glass fiber content (by weight)ASTM D2584%55 – 65
Tensile strengthASTM D638 / EN 13706MPa207 – 35050 – 80
Tensile modulusASTM D638GPa18 – 256 – 9
Flexural strengthASTM D790MPa207 – 35070 – 120
Compressive strengthASTM D695MPa207 – 300100 – 140
Short-beam shear strengthASTM D2344MPa25 – 35
DensityASTM D792g/cm³1.8 – 1.9
24-hour water absorptionASTM D570%≤ 0.6
Coefficient of thermal expansionASTM D69610⁻⁶ /°C8 – 1020 – 30
Thermal conductivity—W/m·K0.3 – 0.6
Flame spread (with fire-retardant resin)ASTM E84—≤ 25 (Class 1)

EN 13706 is the European standard for pultruded profiles. Values are common industry reference ranges for FRP and GFRP composites, not Nabak Composite's own proprietary test results.

FRP Composite Flooring vs. Other Flooring Materials

Table 5 — FRP flooring vs. timber, WPC decking, aluminum and steel checker plate
PropertyGFRP flooringNatural timberWPC deckingAluminumSteel checker plate
Flexural modulus (GPa)18 – 258 – 122 – 570200
Typical beam spacing1000 – 1500 mm400 – 600 mm300 – 400 mm1000 – 1500 mm600 – 1000 mm
Rot and insectsNoneYesLowNoneNone
Corrosion / rustNoneNoneNoneLowSevere
Creep / sagging in heatVery lowLowHighNoneNone
Surface heating in sunlightLowLowModerateHighHigh
Electrical conductivityInsulatorInsulatorInsulatorConductiveConductive
MaintenanceNearly noneAnnual oiling / paintingLowLowPeriodic painting

Why choose FRP flooring over WPC? WPC decking works well on a dense sub-structure, but its modulus is roughly one-fifth to one-tenth that of FRP composite flooring and it sags under heat. With continuous glass-fiber reinforcement, a GFRP deck panel acts as a structural deck directly on steel beams spaced 1–1.5 m apart — like the pedestrian bridge deck shown on this datasheet's cover.

Table 6 — Common durability and safety tests for composite flooring
SubjectReference standardGFRP flooring behavior
UV aging and weatheringASTM G154 / G155Color and surface retained thanks to the UV-resistant polyurethane coating
Slip resistanceDIN 51130 / BS 7976R10 to R13 depending on the finish
Freeze–thaw cycling—No cracking or delamination; negligible water absorption
Salt spray / seawaterASTM B117 (method)No corrosion; suitable for piers and coastal use
FRP flooring technical data | pultruded GFRP composite | fiberglass flooringnabakcomposite.com  |  +98 21 4881 2124  |  @nabak.composite
FRP/GFRP Composite Flooring – Technical DatasheetSection Formulas & Span Table  |  Page 4 of 5

Section Formulas for Composite Flooring Panels

1. Neutral axis of a multi-part section
ȳ = Σ Ai yiΣ Ai

Ai = area of the skin, each web and each foot; yi = distance of its centroid from the bottom. NBK-FD 500/50: ȳ ≈ 39.8 mm (neutral axis near the top skin)

2. Moment of inertia (parallel-axis theorem)
I = Σ ( bi hi³12 + Ai di² )

di = |yi − ȳ|. NBK-FD 500/50: I ≈ 7.62×10⁵ mm⁴ per panel; ≈ 1.52×10⁶ mm⁴ per meter of width

3. FRP flooring surface weight
w = ρ · Abeff   [kg/m²]

ρ = 1.85 g/cm³. NBK-FD 500/50: 1.85 × 3340 / 500 ≈ 12.4 kg/m²

4. Deflection under uniform load
δ = 5 q L⁴384 E · Im ≤ L250

q = surface load (N/mm per meter of width), Im = moment of inertia per meter of width, E ≈ 20 GPa

Span and Deflection Table for Composite Flooring

Table 7 — Calculated deflection (mm) of FRP flooring on two simple supports, and the maximum span for an L/250 deflection limit
Panel / loadL = 800L = 1000L = 1200L = 1500Max. span (mm)
300/40 — 2.5 kPa (residential, balcony)0.811.974.099.991260
300/40 — 4 kPa (public)1.293.166.5516.01080
500/40 — 4 kPa (public)1.413.447.1217.41050
300/50 — 4 kPa (public)0.641.573.267.961360
500/50 — 4 kPa (public)0.701.713.548.651320
500/50 — 5 kPa (pedestrian bridge, assembly)0.882.144.4310.81230

Calculated with Formula 4, the section properties in Table 1 and E = 20 GPa, on two simple supports with no continuity contribution. Struck-through values exceed the L/250 limit. Over three or more supports (continuous panels), deflection is roughly 40–60% lower. This table is a worked example; the final load table for composite flooring must be confirmed by a load test for each order.

5. Deflection of a continuous panel over three supports
δmax = q L⁴185 E Im ≈ 0.42 × δsimple

A long panel running over several beams deflects roughly 58% less than on a simple span — the main reason Nabak offers FRP flooring panels 6–12 m long.

6. Shear deflection contribution from the webs
δs = q L²8 G Aw

G ≈ 3 GPa, Aw = web area per meter of width. 500/50 at 4 kPa and L = 1200: Aw ≈ 1080 mm² → δs ≈ 0.22 mm, about 6% of the flexural deflection; its share is larger on shorter spans.

FRP flooring span table | composite flooring design | GFRP and GRPnabakcomposite.com  |  +98 21 4881 2124  |  @nabak.composite
FRP/GFRP Composite Flooring – Technical DatasheetStress Checks, Details & Installation Guide  |  Page 5 of 5

Stress, Point-Load and Installation Formulas

7. Web-foot flexural stress and safety factor
σb = q beff L² / 8Sbot ,   FS = σuσb

500/50 at q = 5 kPa and L = 1200: M = 450 000 N·mm, Sbot ≈ 19 130 mm³ → σ ≈ 23.5 MPa, FS ≈ 8.8 — deflection governs the design.

8. Panel deflection under a point load
δ = P L³48 E Ipanel

500/50, L = 1200, P = 2 kN (wheel or heavy foot load) on a single panel: δ ≈ 4.7 mm. The tongue-and-groove joint transfers part of the load to the adjacent panel.

9. Thermal expansion joint at panel ends
ΔL = α · L · ΔT

α ≈ 9×10⁻⁶ /°C, a 6000 mm panel, ΔT = 40 °C → ΔL ≈ 2.2 mm; leave a 3–5 mm expansion gap at panel ends.

10. Panel and fastener count
np = ⌈ Bbeff ⌉ ,   Ns = np · nj · k

A 2000 mm-wide bridge deck with 500 mm panels: np = 4; with 11 beams and 2 screws per crossing: Ns = 4 × 11 × 2 = 88 screws

11. Drainage slope on a closed surface
Δh = i · Ld

i = slope (1–2%), Ld = water flow path length. A 4 m path at 1.5% slope → height difference ≈ 60 mm.

12. Surface friction coefficient (ramp test)
μ = tan α

R10 at α = 10° → μ ≈ 0.18; R11 at α = 19° → μ ≈ 0.34; R12 at α = 27° → μ ≈ 0.51

Installing FRP Composite Flooring

  1. Substructure: level the steel or composite support beams and space them per Table 7, perpendicular to the panel's long axis.
  2. First panel: place the first FRP flooring panel square to the beams, with the grooved edge facing the direction of installation.
  3. Tongue-and-groove lock: engage the next panel's hook into the previous panel's groove and seat it with hand pressure or a rubber mallet.
  4. Fastening: fix each panel to every beam with a stainless self-tapping screw or bolt and nut through the web foot or hook edge.
  5. Cutting and sealing: cut panel ends with a diamond blade, seal the cut surface with resin and fit the end cap.
  6. Expansion gaps and drainage: check the 3–5 mm end gap and the 1–2% slope, then clean the surface after installation.

For guard rails beside the flooring see the composite handrail datasheet; for open walking surfaces with more ventilation and drainage see the composite grating datasheet or pultruded grating, and for a closed surface over a grating core see covered composite grating.

What is the difference between FRP composite flooring and composite grating?

Composite grating is an open mesh with roughly 40-70% open area, while FRP composite flooring is a closed pultruded panel with an integral top skin and longitudinal webs that forms a flat, wood-like surface suited to pedestrian bridges, balconies and terraces.

Is FRP flooring better than WPC (wood-plastic composite) decking?

With continuous glass-fiber reinforcement, FRP composite flooring has several times the modulus and strength of WPC decking, deflects less over longer spans, does not sag in heat, and does not rot or swell in damp or marine environments.

How far apart should support beams be under composite flooring?

For a 500×50 mm panel under a 4 kPa load, beam spacing up to about 1300 mm is suitable within the L/250 deflection limit, and for a 500×40 mm panel, up to about 1050 mm.

How is FRP composite flooring installed?

Level the steel or composite support beams and space them according to the span table, perpendicular to the panels' long axis; panels are joined by the tongue-and-groove lock and fixed to every beam with stainless self-tapping screws or bolts and nuts. Panel ends are cut with a diamond blade and sealed with resin, with a 3–5 mm end gap and a 1–2% drainage slope.

What is the slip resistance of composite flooring?

The approximate slip resistance (DIN 51130) depends on the finish: gloss wood grain with a longitudinal groove R10, matte wood grain and grooved grey R10 to R11, and grit-coated with quartz grit R12 to R13. A grit-coated finish is recommended for piers, pools, ramps and oily surfaces.

How light is FRP composite flooring?

The surface weight of Nabak composite flooring panels is roughly 10 to 12.5 kg/m² — about one-twentieth of a 10 cm concrete slab and one-quarter of a 6 mm steel checker plate — so it adds very little dead load to the supporting beams and structure.

Request a quote for FRP composite flooring: please provide the surface length and width, beam spacing, design load, finish type (wood grain, grey or grit-coated) and the service environment.
Nabak Sazeh Gostar  |  nabakcomposite.com  |  +98 21 4881 2124  |  Instagram @nabak.composite

Disclaimer: the information in this technical datasheet is based on general, industry-standard data for FRP and GFRP composites and is provided as guidance. Nabak Composite reserves the right to revise FRP composite flooring specifications without prior notice.

© Nabak Composite — FRP composite flooring and GFRP deckingnabakcomposite.com  |  +98 21 4881 2124  |  @nabak.composite
‹ بازگشت به مرکز اسناد فنی